Series A - Refractive Index Fluids - Individual Liquids

 
Cargille Brand Refractive Index Fluid Series A 0.25 oz (7 ml)
Configuration Standard 1/4 fl
Item9999902-4111-7
AvailabilityContact for Availability
$35.40
 
Cargille Brand Refractive Index Fluid Series A 1 oz (30 ml)
Configuration Economy 1fl.
Item9999902-4111-30
AvailabilityIn Stock
$101.40
 
R. I. Liquid Series A (40z) Range 1.459 - 1.465
Configuration Bulk1.460-1.465
Item19091-4111-120
AvailabilityContact for Availability
$316.80
 
R. I. Liquid Series A (4oz) Range 1.466 - 1.5
Configuration Bulk1.466-1.500
Item19092-4111-120
AvailabilityContact for Availability
$289.28
 
R. I. Liquid Series A (4oz) Range 1.501 - 1.535
Configuration Bulk1.501-1.535
Item19093-4111-120
AvailabilityContact for Availability
$289.28
 
Cargille Brand Refractive Index Fluid Series A (4oz) Range 1.536 - 1.57
Configuration Bulk1.536-1.570
Item19094-4111-120
AvailabilityContact for Availability
$289.28
 
R. I. Liquid Series A (4oz) Range 1.571 - 1.591
Configuration Bulk1.571-1.591
Item19095-4111-120
AvailabilityContact for Availability
$300.48
 
R. I. Liquid Series A (4oz) Range 1.592 - 1.612
Configuration Bulk1.592-1.612
Item19096-4111-120
AvailabilityContact for Availability
$318.40
 
R. I. Liquid Series A (4oz) Range 1.613 - 1.640
Configuration Bulk1.613-1.640
Item19097-4111-120
AvailabilityContact for Availability
$323.52

Individual replacement bottles (any Series A liquid)Be sure to specify exact refractive index desired in the Comments Section of the Order form!

Range: 1.460 to 1.640. Adjusted to ± 0.0002. Stable, colorless at the low end and increasing to faint yellow at the high end.

Composition: Aliphatic hydrocarbons as well as other organic compounds. They are not aqueous based.

Compatibilities: They do appear to be compatible with Plexiglas® or Lucite® acrylics at 25° C.

Absorption information: The Series A Set covers 91 liquids and the transmission values are a function of refractive index, so they vary liquid to liquid. Fortunately, this change is not very great and for most users, is not an issue. But there is a difference in transmission depending on the length of the path. In general, at 480 nm, at a path length of 1mm, the transmittance is nearly 100%, at 1cm this value drops to between 86 to 98% and at 10cm this value drops further to between 23 to 80%. Specially matched refractive index fluids for specific applications are also available. These have been precisely matched are not in general a part of the Series A kit.

A full set of Series A liquids contains a total of 91 different liquids and a half set contains 46 liquids. Each bottle contains 0.25 fl. oz. Listing of nominal refractive index values included in full kit given below, * indicates liquids provided in half kit:

1.460* 1.506 1.552* 1.598
1.462 1.508* 1.554 1.600*
1.464* 1.510 1.556* 1.602
1.466 1.512* 1.558 1.604*
1.468* 1.514 1.560* 1.606
1.470 1.516* 1.562 1.608*
1.472* 1.518 1.564* 1.610
1.474 1.520* 1.566 1.612*
1.476* 1.522 1.568* 1.614
1.478 1.524* 1.570 1.616*
1.480* 1.526 1.572* 1.618
1.482 1.528* 1.574 1.620*
1.484* 1.530 1.576* 1.622
1.486 1.532* 1.578 1.624*
1.488* 1.534 1.580* 1.626
1.490 1.536* 1.582 1.628*
1.492* 1.538 1.584* 1.630
1.494 1.540* 1.586 1.632*
1.496* 1.542 1.588* 1.634
1.498 1.544* 1.590 1.636*
1.500* 1.546 1.592* 1.638
1.502 1.548* 1.594 1.640*
1.504* 1.550 1.596*