Tensile Stress (%) |
Elongation (%) |
At 200% (%) |
At 300% (%) |
Hardness (%) |
Change (%) | |
|
Butadiene - acrylonitrile rubber (NBR) |
- 5 | + 3 | - 14 | - - - | - - - | - 0.3 |
|
Butyl rubber (IIR) |
+ 7 | + 12 | - 10 | - 7 | + 0.7 | + 1.5 |
|
Cloroprene rubber (CR) |
+ 14 | + 18 | - - - | - - - | 0 | - 0.5 |
|
Ethylene- propylene- diens- terpolymer (EPDM) |
+ 14 | + 20 | - 11 | - 8 | + 0.6 | - 0.3 |
|
Fluorocarbon rubber (FKM) |
+ 5 | 0 | + 2 | + 5 | + 5.2 | + 0.3 |
|
Natural rubber (NR) |
+ 6 | + 25 | - 20 | - 15 | - 3.9 | + 2.0 |
|
Polybutadiene cis rubber (BR) |
- 17 | + 7 | - 21 | - - - | - 4.5 | + 8.0 |
|
Styrene butadiene rubber (SBR) |
+ 4 | + 38 | - 38 | - 36 | - 3 | + 0.8 |
|
|
| |
| Aflas 7 |
ASTM D471-79 150EC @ 500 hrs. |
Tensile = - 10.4% Elongation = 1.4% Volume change = - 14.7% |
| DOW 236 |
ASTM D 471-79 200EC @ 500 hrs. |
Change in weight = - 5.4% The material hardened, changed color from white to brown and leeched brownish particulate & globules into the fluid. |
| EPDM |
ASTM D471-79 150EC @ 500 hrs. |
Some leeching into fluid. Compatibility questionable. |
|
Fluorosilicone 60 Duro (XL 2113) |
ASTM D471-79 150EC @ 575 hrs. |
Change in tensile = - 12% Volume cha nge = - 0.1% Change in elongation = - 11.5% |
|
Fluorosilicone 70 Duro (XL 2114) |
ASTM D471-79 150EC @ 500 hrs. |
Change in tensile = - 12.5% Volume change = - 3.5% Change in elongation = - 17% |
| Loctite PST (sealant) |
ASTM D1384-94 150EC @ 336 hrs. 150 ml/min air flow |
Appears compatible. No leeching of sealant into fluid. |
| Loctite 7 Ultra Blue (silicone) | 125EC @ 100 hrs. |
Volume change = - 2.6% Weight change = - 0.2% |
| Silicone RTV (DOW) rubber | 125EC @ 100 hrs. |
Volume change = - 2.7% Weight change = - 0.5% |
| Tecnoflon® FOR 5351 U |
ASTM D 471-79 150EC @ 100 hrs. |
Tensile = 1% Elongation = - 1% Volume Change = 3% |
| Tecnoflon® P 819 |
ASTM D 471-79 150EC @ 500 hrs. |
Tensile = 2% Elongation = - 7% Volume Change = 11% |
| Tecnoflon® FOR 439 |
ASTM D 471-79 150EC @ 500 hrs. |
Tensile = - 13% Elongation = - 4% Volume Change = 9% |
| Tecnoflon® P-710 |
ASTM D 4 71-79 150EC @ 500 hrs. |
Tensile = - 9.3% Elongation = Volume Change = 4.3% |
| Tecnoflon® 5351 |
ASTM D 471-79 200EC @ 500 hrs. |
Tensile = - 4.7% Elongation = 3.9% Volume Change = 8.5% |
|
Viton® fluoroelastomer A Gasket (GASKET NOT 100% VITON A) |
ASTM D 471-79 150EC @ 500 hrs. |
0.32% volume swell Gasket left a lot of filler Not compatible |
|
Viton® fluoroelastomer V115 (TEC V12) International Seals |
ASTM D 471-79 150EC @ 850 hrs. |
Volume change = 3.4% Weight change = 5.5% Change in Hardness = 0.9% Tensile change = - 8% Elongation change = 4.1% |
To Ask a Question or Make a Comment