SPI # 05157-AB and 05157T-AB Castrol® Optitool™ 215-2 Cleanroom Grade Grease

Section 01 Identification


Date Effective........ January 8, 2009 
                   (most recent revision)

Synonyms..............   N/A
Product Use:  Industrial applications

Chemical family....... Salt of alkyl acid phosphate

Chemical formula...... Mixture


Emergencies
                       Contacting CHEMTREC 24 Hour Emergency 
Use Only #'s.......... Worldwide phone : 1-(703)-527-3887
                       Worldwide FAX   : 1-(703)-741-6090
                       Toll-free phone : 1-(800)-424-9300


Product or Trade Name.... Optitool™ 215-2 Cleanroom Grade Grease

Chemical Formula......... Mixture

CAS Number............... 

Hazardous Material
Information System
USA
Health National Fire
Protection Association
USA
Fire Hazard
Reactivity
Personal Protection
NFPA Ratings: Health: Flammability: Reactivity: Other: No Data

Section 2 Composition/Information on Ingredients

This product does not contain any hazardous ingredients at or above regulated thresholds.


Section 3: Hazard Identification

Physical state:
    Grease

Color
     Amber. Grease

Emergency overview
     CAUTION!
     MAY CAUSE EYE IRRITATION.
     MAY CAUSE SKIN IRRITATION.
     MAY CAUSE RESPIRATORY TRACT IRRITATION.

     Avoid contact with eyes. Avoid prolonged or repeated contact
     with skin. Wash thoroughly after handling. Keep container closed.
     Use with adequate ventilation. In accordance with good industrial
     hygiene and safety work practices, airborne exposures should be
     controlled to the lowest extent practicable.

Routes of Entry
      Skin Contact. Eye Contact. Inhalation. Indigestion.

Potential Health Effects
      Eyes             May cause eye irritation
      Skin             May cause skin irritation
      Inhalation       May cause resp irritation
      Ingestion        Ingestion may cause gastrointestinal irritation and diarrhea.

Medical conditions aggravated by overexposure
      Repeated or prolonged exposure is not known to aggravate any medical condition.


Section 4: First Aid Measures

Eye Contact
In case of contact, immediately flush eyes with plenty of water for at least 15
minutes. Get medical attention if irritation develops.

Skin Contact
Immediately wash exposed skin with soap and water. Remove contaminated clothing
and shoes. Wash clothing before reuse. Thoroughly clean shoes before reuse. Get
medical attention if irritation develops.

Inhalation
If inhaled, remove to fresh air. If not breathing, give artificial respiration. If
breathing is difficult, give oxygen. Get medical attention.

Ingestion
Do NOT induce vomiting unless directed to do so by medical personnel. Never give
anything by mouth to an unconscious person. Get medical attention if symptoms
appear.


Section 5: Fire Fighting Measures

Flammability of the product
      May be combustible at high temperature.

Flash point
      >148.89 °C (Open cup) Cleveland.

Products of combustion
      These products are carbon oxides (CO, CO2), nitrogen oxides (NO, NO2...).

Unusual fire/explosion hazards
      This material is not explosive as defined by established regulatory criteria.

Fire fighting media and instructions
      In case of fire, use water spray (fog), foam or dry chemicals.

Protective clothing (fire)
      Fire-fighters should wear positive pressure self-contained breathing apparatus (SCBA) and full turnout gear.

Special remarks on fire hazards
      None identified.

Special remarks on explosion hazards
      None identified.


Section 6: Accidental Release Measures

Personal Precautions
     Immediately contact emergency personnel. Keep unnecessary personnel 
     away. Use suitable protective equipment (See Section: "Exposure 
     controls/personal protection"). Follow all fire fighting procedures 
     (See Section: "Fire-fighting measures").

Environmental precautions and clean-up methods
     If emergency personnel are unavailable vacuum or carefully scoop up 
     spilled materials and place in an appropriate container for disposal. 
     Avoid creating dusty conditions and prevent wind dispersal. Minimize 
     contact of spilled material with soils to prevent runoff to surface
     waterways. See Section 13 for Waste Disposal Information.

Personal protection in case of a large spill
     Splash goggles. Full suit. Boots. Gloves. Suggested protective clothing 
     might not be sufficient; consult a specialist BEFORE handling this product.


Section 7: Handling and Storage


Handling:
Avoid contact with eyes. Avoid contact with skin and clothing. Use 
only with adequate ventilation. Wash thoroughly after handling. Do 
not ingest.

Storage:
Keep container tightly closed. Keep container in a cool, well-ventilated
area. Empty containers may contain harmful, flammable/combustible or explosive 
residue or vapors. Do not cut, grind, drill, weld, reuse or dispose of containers 
unless adequate precautions are taken against these hazards.


Section 8: Exposure Controls and Personal Protection

Occupational exposure limits
     This product does not have any assigned OELs.

Control Measures
     Use process enclosures, local exhaust ventilation, or other engineering 
     controls to keep airborne levels below recommended exposure limits.

Hygiene measures
     Wash hands after handling compounds and before eating, smoking, using 
     lavatory, and at the end of day.

Personal protection

Eyes          Avoid contact with eyes. Safety glasses with side shields 
                     or chemical goggles.
Skin and Body Avoid prolonged or repeated contact with skin. Wear suitable 
                     protective clothing.
Respiratory   Use only with adequate ventilation.
Hands         Wear suitable gloves.

Consult local authorities for acceptable exposure limits.


Section 9: Physical and Chemical Properties

Color             Amber. Grease
Physical state    Grease
Odor              Mild.
Solubility        insoluble in water.
Specific Gravity  0.86


Section 10: Stability and Reactivity

Conditions to avoid                The product is stable.
Incompatibility with various
substances                         Strong oxidizing materials
Hazardous Decomposition Products   Not available.
Hazardous polymerization           Will not occur.


Section 11: Toxicological Information

Chronic toxicity

Carcinogenic effects
     No component of this product at levels greater than 0.1% is identified 
     as a carcinogen by ACGIH or the International Agency for Research on 
     Cancer (IARC). No component of this product present at levels greater 
     than 0.1% is identified as a carcinogen by the U.S. National Toxicology 
     Program (NTP) or the U.S. Occupational Safety and Health Act (OSHA).

Mutagenic effects
     No component of this product at levels greater than 0.1% is classified 
     by established regulatory criteria as a mutagen.

Reproductive effects
     No component of this product at levels greater than 0.1% is classified 
     by established regulatory

Teratogenic effects
     No component of this product at levels greater than 0.1% is classified 
     by established regulatory criteria as teratogenic or embryotoxic.


Section 12: Ecological Information

Ecotoxicological
    No testing has been performed by the manufacturer.
  

Section 13: Disposal Considerations

Waste information
Waste must be disposed of in accordance with federal, state and local environmental
control regulations. Keep out of waterways. Disposal of this material to the land 
may be banned by federal law (40 CFR 268).

RCRA Waste Code(s) USED OIL

Consult your local or regional authorities.


Section 14: Transport Information

Not classified as hazardous for transport (DOT, TDG, UN , IMO, IATA/ICAO).


Section 15: Regulatory Information

US INVENTORY (TSCA): In compliance. U.S. Federal regulations
                     This product is not regulated under Section 302 of SARA
                     and 40 CFR Part 355.

SARA 313
Form R - Reporting 
Requirements    This product does not contain any hazardous ingredients at or
                above regulated thresholds.


Section 16: Other Information

Disclaimer of Liability:

Caution!  Do not use SPI Supplies products or materials in applications 
involving implantation within the body; direct or indirect contact with 
the blood pathway; contact with bone, tissue, tissue fluid, or blood; or 
prolonged contact with mucous membranes.  Products offered by SPI Supplies 
are not designed or manufactured for use in implantation in the human body 
or in contact with internal body fluids or tissues.  SPI Supplies will not 
provide to customers making devices for such applications any notice, 
certification, or information necessary for such medical device use 
required by US FDA (Food and Drug Administration) regulation or any 
other statute. SPI Supplies and Structure Probe, Inc. make no 
representation, promise, express warranty or implied warranty c
oncerning the suitability of these materials for use in implantation 
in the human body or in contact with internal body tissues of fluids.

********************************************************************** 

The information and recommendations set forth above are taken from sources
believed to be accurate as of the date hereof, however SPI Supplies and 
Structure Probe, Inc. make no warranty with respect to the accuracy of the 
information or the suitability of the recommendations, and assume no liability 
to any user thereof. The information contained in this sheet does not
constitute a hazard assessment and should not be used in place of the user's
own assessment of work place risks as required by other health and safety 
legislation. Be aware of the Structure Probe, Inc. Copyright Policy. Structure 
Probe, Inc. grants a nonexclusive license to make unlimited copies of this safety 
sheet for internal use only. Quite obviously, this information would pertain only 
to this material when purchased from SPI Supplies as product from other sources, 
with other ingredients and impurity levels could have substantially different 
properties. 


To Ask a Question or Make a Comment

To Place an Order or Request a Quote


Return to:
Tuesday May 22, 2012
© Copyright2012. By Structure Probe, Inc.
Contacting SPI Supplies and Structure Probe, Inc.
All rights reserved.
All trademarks and trade names are the property of their respective owners.
Privacy Policy

Worldwide Distributors, Representatives, and Agents Flag logo