Date Effective.......... November 7, 2006
(most recent revision)
Chemical Name/Synonyms... not available
Emergencies
Contacting CHEMTREC:
24 Hour Emergency Use Only #'s...
Worldwide phone: 1-(703)-527-3887
Worldwide FAX: 1-(703)-741-6090
Toll-free phone: 1-(800)-424-9300 USA only
Product or Trade Name...SPI #05142-AB
Braycote® 1625 Perfluoropolyether Vacuum Grease
| Hazardous
Material Information System USA | Health | 3 | National Fire Protection Association USA | ![]() |
| Fire Hazard | 1 | |||
| Reactivity | 0 | |||
| Personal Protection |
This product does not contain any hazardous ingredients at or above regulated thresholds.
Emergency overview: Caution! May cause eye irritation, skin irritation, respiratory tract irritation. Appearance: Clear, colorless liquid Flash Point: Not available Potential Health Effects Eye: May cause eye irritation. Skin: May cause skin irritation. Ingestion: May cause gastrointestinal irritation and diarrhea. Inhalation: May cause respiratory tract irritation. Chronic: None known.
Eyes: In case of eye contact, flush eyes with copious amounts of water for at least 15 minutes. Seek medical attention if irritation occurs. Skin: Wash affected area with plenty of soap and water immediately. Remove contaminated clothing and launder before reuse. Remove contaminated shoes and clean thoroughly before reuse. Seek medical attention if irritation occurs. Ingestion: Do NOT give anything by mouth to an unconscious person. Do NOT induce vomiting unless directed to do so by medical professional. Seek medical attention if symptoms occur. Inhalation: If inhaled, remove to fresh air. If breathing is difficult, give oxygen. If breathing stops, provide artificial respiration. Seek medical attention if symptoms develop. Notes to Physician: Treat symptomatically and supportively.
General Information: Product may be combustible at high temperatures. Product is not explosive with respect to open flames, sparks, static discharge, shocks, or mechanical impacts. Extinguishing Media: Water fog, foam, dry chemicals or carbon dioxide. Protective Gear: Use self-contained breathing apparatus (SCBA) and skin protection for acid gas exposure. Do not enter fire area without proper protection. Fight fire from safe distance. If possible, air monitoring should be performed. Products of Combustion: Carbon monoxide, Carbon dioxide, halogenated compounds, Hydrogen fluoride. Hydrogen fluoride has an ACGIH TLV ceiling limit of 3 ppm (2.6 mg/m3) and an OSHA PEL TWA of 3 ppm. Carbonyl fluoride has an ACGIL TLV and OSHA PEL TWA of 2 ppm (5 mg/m3).
General Information: Keep unnecessary personnel away. Wear suitable protective gear. Spills/Leaks: Large spills: Wear appropriate protective clothing. Stop source of leak if possible. Dike, contain spill and recover free liquid. Prevent entry into waterways. Soak up residue with an inert absorbent such as clay, sand or other suitable materials; Store and dispose of properly. Small spills: Soak up spill with inert absorbent. Store in a closed, liquid-proof container and dispose of properly. Personal Protection in case of a large spill: Chemical splash goggles, full protective suit, boots, gloves. Consult a specialist BEFORE handling a large spill.
Handling: Avoid eye contact, skin contact, clothing contact, inhalation. Use only with adequate ventilation, keeping airborne exposures as low as possible. Wash thoroughly after handling. Storage: Store in tightly closed containers in cool, well-ventilated area. Do not cut, grind, drill, weld, reuse, or dispose of containers unless adequate precautions have been taken to remove harmful, flammable, combustible or explosive residue or vapors.
Engineering Controls: Provide adequate exhaust ventilation to keep airborne concentrations below occupational exposure limits. Exposure Limits: Chemical Name ACGIH NIOSH OSHA - Final PELs Braycote 1625 none none none OSHA Vacated PELs: none Personal Protective Equipment Eyes: Chemical splash goggles Skin: Wear suitable chemical resistant gloves. Clothing: Wear suitable protective clothing to prevent skin contact. Respirators: Use only with adequate ventilation. Control airborne exposures to lowest possible extent practicable.
Physical State: Liquid Appearance: clear, colorless Odor: Mild pH: Not available Vapor Pressure: Not available Vapor Density: Not available Evaporation Rate: Not available Viscosity: Not available Boiling Point: 500°C Freezing/Melting Point: Not available Autoignition Temperature: Not available Flash Point: Not available Decomposition Temperature: Not available Explosion Limits: Lower: Not available Upper: Not available Solubility in water: Insoluble Specific Gravity/Density: 1.8-2.0 Molecular Formula: Not available Molecular Weight: Not available
Chemical Stability: Stable Conditions to Avoid: Excessive heat Incompatibility with Other Materials: Oxidizing materials, metals, acids and alkalis Hazardous Decomposition of Products: Carbon monoxide, Carbon dioxide, Hydrogen Fluoride Hazardous Polymerization: Will not occur
Carcinogenicity: No component of this product present a >0.1% is identified as a carcinogen by ACGIH, IARC, NTP, or OSHA. Teratogenicity: No component of this product present at >0.1% is classified as a teratogen or embryonic toxin. Reproductive Effects: No component of this product present at >0.1% is classified as a reproductive toxin. Mutagenicity: No component of this product present at >0.1% has been classified as a mutagen. Other Studies: Not available.
No testing has been carried out by the manufacturer.
Use only approved transporters, recyclers, or facilities for treatment, storage and/or disposal of this product. Dispose of in accordance with all applicable federal, state and local regulations.
US DOT Hazard Class: This product is not classified as hazardous for transport by DOT. IATA (for international shipments) This material is not classified as hazardous for transport by IATA/ICAO.
United States: TSCA This product is in compliance with the TSCA Inventory. CERCLA: This product is not regulated under CERCLA Sections 103 and 107. SARA: Section 302: This product is not regulated under SARA Section 302 and 40 CFR Part 355. SARA Codes Section 313/312: Brayco 1625: Immediate (Acute) Health Hazard This product does not have any hazardous ingredients at or above regulated thresholds. OSHA: This product does not have any Occupational Exposure Limits. State (Individual states in the USA) Not listed. California No Significant Risk Level: Not listed. California Prop. 65: Not listed. EC Inventory: Not listed Risk Phrases: R36/37/38 Irritating to eyes, respiratory system and skin. Safety Phrases: S2 Keep out of the reach of children. S36/37/39 Wear suitable protective clothing, gloves and eye/face protection. S51 Use only in well-ventilated area. Canada This product is in compliance with the Canada Inventory (DSL). WHMIS: This product has a classification of B3.
Disclaimer of Liability: Caution! Do not use SPI Supplies products or materials in applications involving implantation within the body; direct or indirect contact with the blood pathway; contact with bone, tissue, tissue fluid, or blood; or prolonged contact with mucous membranes. Products offered by SPI Supplies are not designed or manufactured for use in implantation in the human body or in contact with internal body fluids or tissues. SPI Supplies will not provide to customers making devices for such applications any notice, certification, or information necessary for such medical device use required by US FDA (Food and Drug Administration) regulation or any other statute. SPI Supplies and Structure Probe, Inc. make no representation, promise, express warranty or implied warranty concerning the suitability of these materials for use in implantation in the human body or in contact with internal body tissues of fluids. This product is intended for external contact only with human skin.
To Ask a Question or Make a Comment