SPI Supplies Division
|
Date Effective........... January 16, 2006
(most recent revision)
Chemical Name/Synonyms... not available
Emergencies
Use Only #'s...........
Contacting CHEMTREC 24 Hour Emergency
Worldwide phone: 1-(703)-527-3887
Worldwide FAX: 1-(703)-741-6090
Toll-free phone: 1-(800)-424-9300 USA only
Product or Trade Name.... SPI #05141-AB
Brayco® 1624 Perfluoropolyether Lubricant
| Hazardous
Material Information System USA | Health | 3 | National Fire Protection Association USA | ![]() |
| Fire Hazard | 1 | |||
| Reactivity | 0 | |||
| Personal Protection |
Component Name CAS # Percent EINECS/ELINCS Not known.
Emergency overview: Caution! May cause respiratory tract, eye and skin
irritation. Avoid contact with eyes, skin and clothing. Avoid breathing
vapor or mist. Keep container closed. Use with adequate ventilation.
Wash thoroughly after handling. Do not ingest.
Appearance: Clear. Colorless. Liquid.
Flash Point: Not available
Target Organs: Not available
Potential Health Effects:
Eye: Moderately irritating to the eyes.
Skin: Moderately irritating to the skin.
Ingestion: Ingestion may cause gastrointestinal irritation and
diarrhea.
Inhalation: Moderately irritating to the respiratory system.
Chronic:
Carcinogenic Effects: No component of this product a levels
greater than 0.1% is identified as a carcinogen by ACGIH or IARC.
Mutagenic Effects: No component of this product a levels greater
than 0.1% is classified by regulatory criteria as a mutagen.
Teratogenic Effects: No component of this product at levels greater
than 0.1T is classified by established regulatory criteria as
teratogenic or embryotoxic.
Medical Conditions Aggravated by Overexposure: Repeated or prolonged exposure
is not known to aggravate medical condition.
Eyes: Check for and remove any contact lenses. In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Seek medical attention. Skin: In case of contact, immediately flush skin with plenty of water. Cover the irritated skin with an emollient. Remove contaminated clothing and shoes. Wash clothing before reuse. Thoroughly clean shoes before reuse. Seek medical attention. Ingestion: Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If large quantities of this material are swallowed, call a physician immediately. Loosen tight clothing, such as collar, tie, belt, waistband. Inhalation: If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Seek medical attention. Notes to Physician: Not available.
General Information: May be combustible at high temperature. Products of combustion are carbon monoxide, carbon dioxide, and hydrogen fluoride. Non-explosive in presence of open flames, sparks and static discharge, or shocks. Extinguishing Media: Small Fire: Use DRY chemical powder. Large Fire: Use water spray, fog or foam. Do not use water jet. Cool closed containers exposed to fire with water. Use and approved/certified respirator or equivalent. Special Remarks: A NFPA health hazard rating of "3" is assigned due to toxicity of thermal decomposition products and fluorine (HF); otherwise, the material itself warrants a health hazard rating of "1".
General Information: Absorb with an inert material and put the spilled material in an appropriate waste disposal container. Spills/Leaks: Absorb with an inert material and put the spilled material in an appropriate waste disposal container. Do not allow to enter drains or watercourses.
Handling: Avoid contact with eyes, skin and clothing. Avoid breathing vapors or spray mists, Keep container closed. Use with adequate ventilation. Wash thoroughly after handling. Do not ingest. Storage: Store in cool, well-ventilated area. Keep tightly closed and sealed until ready to use. Avoid contact with strong oxidizers, excessive heat, sparks or open flame. Empty containers may contain harmful, flammable/combustible or explosive residue or vapors. Do not cut, grind, drill, weld reuse or dispose of containers unless adequate precautions are taken against these hazards.
Engineering Controls: Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective occupational exposure limits. Ensure that eyewash stations and safety showers are available to the work area. Provide exhaust ventilation if temperature is expected to exceed 260 degrees C. Exposure Limits: Chemical Name ACGIH NIOSH OSHA - Final PELs No hazardous ingredients. Personal Protective Equipment Eyes: Use safety glasses with side shield or chemical safety goggles. Skin: Use impervious gloves. Clothing: Use synthetic apron. Wear protective clothing to prevent skin contact. Respirators: Respiratory protection is not required for the use of this product. Wear appropriate respirator when ventilation is inadequate.
Physical State: Liquid
Appearance: Clear, Colorless
Odor: Mild
pH: Not available
Vapor Pressure: Not available
Vapor Density: Not available
Evaporation Rate: Not available
Viscosity: 22.0-28.0 cSt @40° C
Boiling Point: >260° C (500° F)
Freezing/Melting Point: Not available
Autoignition Temperature: Not available
Flash Point: Not available
Decomposition Temperature: Not available
Explosion Limits, Lower: Not available
Upper: Not available
Solubility in water: Insoluble in cold water
Specific Gravity/Density: 1.8 to 2 (Water = 1)
Molecular Formula: Not available
Molecular Weight: Not available
Chemical Stability: This product is stable. Conditions to Avoid: Not known. Incompatibility with Other Materials: Reactive with oxidizing agents, metals, acids, alkalis. Hazardous Decomposition of Products: Carbon monoxide, Carbon dioxide, Hydrogen Fluoride Hazardous Polymerization: Will not occur.
RTECS#: Not available. CAS#: Not available. LD50/LC50 Information: Not available. CAS #: Carcinogenic Effects: No component of this product a levels greater than 0.1% is identified as a carcinogen by ACGIH or IARC. Mutagenic Effects: No component of this product a levels greater than 0.1% is classified by regulatory criteria as a mutagen. Teratogenic Effects: No component of this product at levels greater than 0.1T is classified by established regulatory criteria as teratogenic or embryo-toxic.
Exotoxicity: Not available. Environmental Fate: Not available. Aquatic: Not available. Atmospheric: Not available. Physical: Not available. Products of Degradation: Carbon monoxide, Carbon dioxide, Hydrogen Fluoride.
RCRA Waste Code: USED OIL Waste must be disposed of in accordance with federal, state and local environmental control regulations. Consult your local or regional authorities. Large Spills: Wear appropriate protective clothing. Stop source of leak if possible. Dike, contain spill and recover free liquid. Prevent entry into waterways. Soak up residue with an inert absorbent material such as clay or sand. Store and dispose of properly. Flush area with water. Small Spills: Neutralize and or soak up spill with inert absorbent. Store in a closed container for disposal. All recovered material should be packaged, transported and dispose of in accordance with local, state and federal regulations. Do not burn materials contaminated with this product.
US DOT Hazard Class: Not regulated. ADR/RID Classification: Not determined. IMO/IMDG Classification: Not determined. IATA (for international shipments): Not determined.
United States: TSCA 8(b) Inventory: All components of this product are listed on, or meet the exemption requirements of, the applicable inventory list. SARA: Section 302 (RQ): Not found. Section 302 (TPQ): Not found. SARA Codes Section 311/312: MSDS distribution - chemical inventory - hazard identification: BRAYCO 1624: Immediate health hazard. Section 313: No products found. Clean Air Act: No products found. Clean Water Act: No products found. OSHA, IARC, NTP: No component known to be present in this product at >0.1% is presently listed as a carcinogen. TSCA Inventory: This product is a mixture and is NOT listed in the TSCA Inventory. The individual ingredients in the product are listed in the TSCA Inventory. State (Individual states in the USA): No products found. California No Significant Risk Level: No products found. California Prop. 65: No products found. CEPA DSL: All components of this product are listed on, or meet the exemption requirements of, the applicable inventory list. AUSTRALIA (NICNAS): One or more of the materials contained in this product may not appear on the applicable inventory list. Please consult the manufacturer (Castrol: 630-241-4000) for additional information. KOREA (TCCL): One or more of the materials contained in this product may not appear on the applicable inventory list. Please consult the manufacturer (Castrol: 630-241-4000) for additional information. PHILIPPINES (RA6969): One or more of the materials contained in this product may not appear on the applicable inventory list. Please consult the manufacturer (Castrol: 630-241-4000) for additional information. MITI: One or more of the materials contained in this product may not appear on the applicable inventory list. Please consult the manufacturer (Castrol: 630-241-4000) for additional information. EINECS: One or more of the materials contained in this product may not appear on the applicable inventory list. Please consult the manufacturer (Castrol: 630-241-4000) for additional information.
Disclaimer of Liability: Caution! Do not use SPI Supplies products or materials in applications involving implantation within the body; direct or indirect contact with the blood pathway; contact with bone, tissue, tissue fluid, or blood; or prolonged contact with mucous membranes. Products offered by SPI Supplies are not designed or manufactured for use in implantation in the human body or in contact with internal body fluids or tissues. SPI Supplies will not provide to customers making devices for such applications any notice, certification, or information necessary for such medical device use required by US FDA (Food and Drug Administration) regulation or any other statute. SPI Supplies and Structure Probe, Inc. make no representation, promise, express warranty or implied warranty concerning the suitability of these materials for use in implantation in the human body or in contact with internal body tissues of fluids.********************************************************************** The information and recommendations set forth above are taken from sources believed to be accurate as of the date hereof, however SPI Supplies and Structure Probe, Inc. make no warranty with respect to the accuracy of the information or the suitability of the recommendations, and assume no liability to any user thereof. The information contained in this sheet does not constitute a hazard assessment and should not be used in place of the user's own assessment of work place risks as required by other health and safety legislation. Remember that it is always, at all times, the user's responsibility to determine the suitability of any material for any specific purpose and to adopt such safety precautions as may be necessary.