SPI Supplies Division
Section 01 Identification
Date Effective........... February 17, 2007
(most recent revision)
Chemical Name/Synonyms... Polymer combination with
resins and greases
Chemical family.......... Not known
Emergencies
Contacting CHEMTREC 24 Hour Emergency
Use Only #'s............. Worldwide phone : 1-(703)-527-3887
Worldwide FAX : 1-(703)-741-6090
Toll-free phone : 1-(800)-424-9300
Product or Trade Name.... SPI # 05058-AB Tempfix Mounting Adhesive
CAS #.................... Not asigned
Chemical Formula......... Not available
Description:
Polymer combination of resin and greases.
Emergency overview:
This material is not hazardous by OSHA Hazard Communication
Definition
Physical Health Hazards:
Dust may form explosive mixtures with air. Molten polymer may
cause thermal burns. Irritating fumes may be produced at
elevated temperatures.
Physical state: Solid
Color: Clear
Odor: None at room temperature
Odor threshold: No data available
Potential Health Effects:
Routes of exposure:
Eye contact, ingestion, skin contact are all highly unlikely.
Signs and Symptoms of Acute Exposure:
Molten polymer may cause thermal burns. At process temperature,
irritating fumes may cause soreness in the nose and throat,
coughing may result. Mechanical irritation is possible.
Skin contact:
Molten polymer may cause thermal burns
Inhalation:
At process temperatures irritating fumes may be produced.
Inhalation of process fumes may cause soreness in the nose
and throat and coughing. Inhaling Tempfix dust could be
irritating.
Eye contact:
Mechanical irritation is possible if the material is
abraided into a powder.
Ingestion:
Ingestion is unlikely
Chronic Health Effects Summary:
No known chronic health effects.
Conditions Aggravated by Exposure:
No known conditions are aggravated by this material.
Take proper precautions to ensure your own health and safety before
attempting to rescue and providing first aid. For specific information
refer to the Emergency Overview in Section of this MSDS. Good laboratory
hygeine practices should be observed at all times.
Inhalation:
If symptoms are experienced, move victim to fresh
air, if symptoms persist, obtain medical attention.
Eye Contact:
Wash eyes with clean low-pressure water. If irritation
persists, seek medical advice. This situation would arise
only if the product is abraided into a powder.
Skin Contact:
If molten material contacts the skin, immediately
flush the skin with large amounts of water to cool
the affected tissue and polymer. Do not attempt to
peel polymer from skin. Get medical attention immediately.
Ingestion:
Adverse health effects due to ingestion are not
anticipated. If gastric irritation or discomfort
persists, seek medical advice.
Special Conditions to Avoid:
Polyisobutylene dust particles in the atmosphere can be combustible
and may be explosive. Keep away from heat, sparks, flame and all
other ignition sources. Keep container closed. Clean up dust
accumulations. Prevent dust accumulations and dust clouds.
Extinguishing Media:
Use extinguishing media suitable for surrounding fire. Unsuitable
extinguishing media for safety reasons is full water jet.
Fire and Explosure Hazard:
May evolve cabon monoxide and carbon dioxide
Special protective equipment:
Use self containing breathing apparatus.
Precautionary measures related to people:
Caution: Surfaces covered with the material may become slippery.
Environmental protective measures: No special requirements.
Methods of cleaning/absorption: Remove mechanically
Handling:
Ensure that the area is well ventilated. Extraction hood
recommended. No other special precautions required.
Avoid breathing vapors when heated.
Storage:
No special precautions or requirements.
Engineering Controls:
If user operations generate dust or fumes, ventilate area
to prevent accumulation.
Personal protection:
General:
Always observe good laboratory hygeine practices.
Eye:
Always use safety glasses, even for work with small
quantities, such as the mounting of samples for SEM
examination.
Ingredients with threshold limit values to be monitored: None
Appearance: Solid, pale yellow
Odor: None
Boiling Point/Range: > 400° C
Flash point: > 200° C
Ignition Temperature: Not available
pH: Not applicable
Vapor Pressure: Not applicable
Viscosity: Not applicable
Specific Gravity:
Solid/Liquid 0.95 g/cc
Vapor Not applicable
Water solubility:
Insoluble
Octanol/Water Partition Coefficient in Kow:
Specific value not known
Melting/Freezing Point:
Not known
Evaporation Rate:
Not applicable
Chemical Stability:
The product is stable.
Conditions to Avoid:
Avoid contact with strong oxidizers, excessive heat, sparks
or open flame or dust accumulation.
Incompatibility with:
Chlorine, fuming nitric acid and strong oxidizing agents.
Hazardous Products of Deposition:
Hydrocarbons, acetic acid
Reactions with Air and Water:
Does not react with air, water or other common materials.
Summary: Not considered to be toxic to humans or animals. No evidence of harmful effects in the case of the intended use for SEM sample preparation.
Exotoxicity:
Exotoxicity is expected to be low based on the low water
solubility of polyisobutylene.
Environmental Fate:
No information found in our selected references.
Bioaccumulation:
Not expected to occur.
This material is NOT classified as a hazardous material by RCRA. Use only licensed transporters and permitted disposal facilities and conform to all laws. Product and packaging must be disposed of in accordance with local and national regulations after consultation with the competent local authorities and the disposal company in a suitable and licensed facility. German Waste Code: LAGA 57129 "Sonstige ausgehärtete Kunststoffabfälle"
Proper Shipping Name: Not Regulated DOT Hazard Class: Non-Regulated UN/NA ID: Not Regulated Packing Group: Not Applicable Labels: Not Regulated Marine Pollutant: No NAER Guidebook: Not Regulated DOT Status: Not Regulated
TSCA:
All components of this product are listed on the TSCA 8(b)
inventory. If identified components of this product are listed
under the TSCA 12(b) Export Notification Rule, they will be
listed below.
TSCA 12(b) Component Listed under TSCA Section
SARA-Section 313 Emissions Reporting:
Component Reporting Threshold
SARA-Section 311/312:
No components present in this product are subject to the reporting
requirements of this statute.
CERCLA Hazardous Substances and their Reportable Quantities:
Component Reportable Quantity
California Prop. 65:
Proposition 65 requires manufacturers or distributors of consumer
products into the State of California to provide a warning statement if
the product contains ingredients for which the State has found to cause
cancer, birth defects or other reproductive harm. If this product
contains an ingredient listed by the State of California to cause cancer
or reproductive toxicity, it will be listed below:
Disclaimer of Liability: Caution! Do not use SPI Supplies products or materials in applications involving implantation within the body; direct or indirect contact with the blood pathway; contact with bone, tissue, tissue fluid, or blood; or prolonged contact with mucous membranes. Products offered by SPI Supplies are not designed or manufactured for use in implantation in the human body or in contact with internal body fluids or tissues. SPI Supplies will not provide to customers making devices for such applications any notice, certification, or information necessary for such medical device use required by US FDA (Food and Drug Administration) regulation or any other statute. SPI Supplies and Structure Probe, Inc. make no representation, promise, express warranty or implied warranty c oncerning the suitability of these materials for use in implantation in the human body or in contact with internal body tissues of fluids.
To Ask a Question or Make a Comment
To Place an Order or Request a Quote