Material Safety Data Sheet

SPI #04993-AB Silver Filled Conductive Grease


Section 01: Identification


Date Effective... January 8, 2009
              (most recent revision)

Chemical Name/Synonyms:  Mixture

Chemical Family... Silver colloid in silicone fluid

Emergencies

Use Only #'s........... 
Contacting CHEMTREC 24 Hour Emergency
Worldwide phone:  1-(703)-527-3887
Worldwide FAX:    1-(703)-741-6090
Toll-free phone:  1-(800)-424-9300 USA only

Product or Trade Name.... SPI #04993-AB Silver Filled Conductive Grease

CAS #.................... Mixture, see below for individual components

Chemical Formula......... Mixture

Main use................. Wherever a conductive lubricant is needed
such as in the lubrication of substation switches or circuit breakers.

Secondary use:  Heat dissipation from transformers

Hazardous Material
Information System
USA
Health 1 National Fire
Protection Association
USA
Fire Hazard 1
Reactivity 0
Personal Protection
NFPA and HMIS Codes: NFPA HMIS Health 1 1 Flammability 1 1 Reactivity 0 0 Personal Protection - B


Section 2: Composition


       CAS Number            Ingredients            %

       7440-22-4           Silver (metallic)      55-85
       Non-hazardous       Silicone Oil           15-45

Occupational exposure limits:



Section 3: Physical and Chemical Properties - Hazards Overview


Physical state:         Silver/gray/grease
Odor:                   No odor
pH:                     Not applicable
Vapor pressure:         Not available
Vapor density:          Not available
Solubility in water:    < 1%
Specific gravity:       2.4 - 2.7
Evaporation rate (butyl acetate=1): slower
Boiling range:          Not available
Percent volatile:       < 2.0



Section 4: Handling and Storage


Overheating may cause container to rupture.  Use explosion proof
electrical equipment.  Containers must be kept closed and ventilation
provided to prevent vapor concentration build-up.  Store in a cool dry
place.  Do not breath vapor or get liquid in eyes, or on skin and clothing.
Keep away from heat or sources of ignition.   Check all containers for
leaks.  Wear protective clothing as in section above.  Avoid prolonged
breathing of vapors or contact with skin.  Ensure that all equipment is
grounded to prevent static discharge.  Containers of this material may be
hazardous when emptied due to solid or vapor residue.  All hazard
precautions given in this data sheet must be observed for empty containers.
Keep out of reach of children.




Section 5: Stability and Reactivity


Stability:  This product is stable.

Conditions to Avoid:  Contamination with incompatible materials.

Incompatibility:  Avoid strong oxidizing agents, strong acids and bases.

Products of Decomposition:  Carbon monoxide, carbon dioxide, silicon
dioxide, oxides of nitrogen, and incompletely burned hydrocarbons which
may include traces of formaldehyde.


Hazardous Polymerization:  May not occur.

Conditions to avoid:  None known.



Section 6: Hazards Identification

      

Emergency Overview:
Silver/gray grease with no odor.  This product is nonflammable.
Liquid will irritate eyes and skin.

Potential Health Effects:

Eyes:
Liquid and vapors of this product may cause temporary discomfort
with mild redness.

Skin:
Not expected to be a skin irritant.  Repeated and prolonged skin
contact is not known to have any adverse effects.

Ingestion:
Harmful if swallowed.  Expected to be slightly toxic by ingestion.
Silver ingestion may result in generalized argyria.

Inhalation:
No specific information available.  Not known to be a respiratory irritant.

Pre-Existing Medical Conditions Aggravated by Exposure:
Eye



Section 7: Exposure Controls/Personal Protection


Exposure Guidelines:

CHEMICAL NAME          ACGIH TLV     OSHA PEL     ACGIH STEL

Silver                 0.1 mg/m3     0.01mg/m3       NA
Silicone Oil               NA            NA          NA

Work/Hygienic Practices:
Good general ventilation should be sufficient to control airborne
levels.  Local exhaust ventilation may be necessary to control any
air contaminants to within their TLVs during the use of  this product.
Wear safety glasses with side shields or goggles and rubber or other
chemically resistant gloves when handling this material.




Section 8: First Aid Measures


Eyes:
Immediately flush with large amounts of water.  After initial flushing,
remove any contact lenses and continue flushing for at least 15 minutes.
Have eyes examined by a Physician.

Skin:
Remove contaminated clothing and wash skin with soap and water.
Get medical attention if irritation develops/persists.  Wash clothes
separately before reuse.

Ingestion:
If appreciable quantities are swallowed, seek medical attention.

Inhalation:

Not likely route of exposure.  If inhaled and irritation occurs,
remove to fresh air.  If irritation persists, call a Physician.



Section 9: Fire Fighting Measures


Flash Point:  > 271°C/520°F (Setaflash) EL/UEL:  NA (% by volume in air)

Extinguishing Media:
Use carbon dioxide or dry chemicals for small fires, aqueous foam or
water for large fires involving this material. 

Fire Fighting Instructions:
Remove all ignition sources.  Closed containers may rupture due to
build-up of pressure when exposed to extreme heat.  Fight fire from
a safe distance.  As in any fire, wear self-contained breathing
apparatus (pressure demand, OSHA/NIOSH approved or equivalent) and
full protective gear.




Section 10: Accidental Release Measures


Large Spills:
Remove all sources of ignition (sparks, open flames, etc.).  Wear
self-contained breathing apparatus and appropriate personal protective
equipment.  Ventilate area and contain spill with sand or other absorbent
material.  Collect spill by scooping up liquids and absorbent material
and place in a sealed metal container for proper disposal.  Do not flush
to sewer.  Prevent material from entering storm sewers, ditches that lead
to waterways and ground.

Small Spills:
Absorb spill with absorbent material, then place in a sealed
metal container for proper disposal.

Note:  A large spill is highly unlikely with this material both
because of the small quantity containers and also its relatively
high viscosity.



Section 11: Toxicological Information


                 LD50                           LC50(ppm)
Ingredients (rat)    Oral (rbt)       Dermal (rat)     Inhalation

Silver (metallic)  > 10 gm/kg (mouse)      NA             NA
Silicone Oil            NA                 NA             NA

Cancer Information:
No ingredients listed as human carcinogens by NTP or IARC 



Section 12: Ecological Information


Environmental Impact Information:
Avoid runoff into storm sewers and ditches which lead to waterways.
Water runoff can cause environmental damage.

Reporting:
US regulations require reporting spills of this material that
could reach any surface waters.  The toll free number for the
US Coast Guard National Response Center is:  1-800-424-8802 



Section 13: Disposal Considerations


Dispose of in accordance with all federal, state and local regulations.
Water runoff can cause environmental damage.

Recycle to process, if possible.  Silver is a non-renewable resource.



Section 14: Transport Information


Proper Shipping Name:  Adhesives, sealants

DOT Hazard Class:  Not regulated

UN/NA ID:  Not regulated

Packing Group:  Not applicable

Marine Pollutant:  Not known



Section 15: Regulatory Information


TSCA:  All components of this product are listed on the TSCA 8(b)
       inventory.  If identified components of this product are
       listed under the TSCA 12(b) Export Notification Rule, they
       will be listed below.

       TSCA 12(b) Component      Listed under TSCA Section

All ingredients of this product are listed on the TSCA inventory listing.

SARA-Title 3, Section 313 Emissions Reporting Information (40 CFR 372)


Product contains no SARA Title 3, Section 313 listed chemicals.

WHMIS:
Ingredient disclosure list:  None
Status:  Uncontrolled

California Prop. 65:
Proposition 65 requires manufacturers or distributors of consumer products
into the State of California to provide a warning statement if the product
contains ingredients for which the State has found to cause cancer, birth
defects or other reproductive harm.  If this product contains an ingredient
listed by the State of California to cause cancer or reproductive toxicity,
it will be listed below:

No such materials found in this product.



Section 16: Other Information


If this product should be used in ways that are outside of the intended
applications and if it is going to be formulated into some other system,
so that it becomes just another component of that other system, read the
MSDS sheets for the other components before blending as the resulting
mixture may have the hazards of all of its parts.

Disclaimer of Liability:

Caution!  Do not use SPI Supplies products or materials in applications
involving implantation within the body; direct or indirect contact with
the blood pathway; contact with bone, tissue, tissue fluid, or blood;
or prolonged contact with mucous membranes.  Products offered by SPI
Supplies are not designed or manufactured for use in implantation in
the human body or in contact with internal body fluids or tissues.
SPI Supplies will not provide to customers making devices for such
applications any notice, certification, or information necessary for such
medical device use required by US FDA (Food and Drug Administration)
regulation or any other statute. SPI Supplies and Structure Probe, Inc.
make no representation, promise, express warranty or implied warranty
concerning the suitability of these materials for use in implantation
in the human body or in contact with internal body tissues of fluids.

**********************************************************************
The information and recommendations set forth above are taken from sources believed to be accurate as of the date hereof, however SPI Supplies and Structure Probe, Inc. make no warranty with respect to the accuracy of the information or the suitability of the recommendations, and assume no liability to any user thereof. The information contained in this sheet does not constitute a hazard assessment and should not be used in place of the user's own assessment of work place risks as required by other health and safety legislation.

To Ask a Question or Make a Comment

To Place an Order or Request a Quote


Return to:
Wednesday February 08, 2012
© Copyright 2012. By Structure Probe, Inc.
Contacting SPI Supplies and Structure Probe, Inc.
All rights reserved.
All trademarks and trade names are the property of their respective owners.
Privacy Policy

Worldwide Distributors, Representatives, and Agents Flag logo