
Date Effective..........January 8, 2009
(most recent revision)
Chemical Name/Synonyms..NanoplastŪ Resin;
MME 7002; Non-plastified melamine resin;
Hexamethylolmelamine methyl ether;
Hexamethoxymethylmelamine;
N-hexamethylolmelamine hexamethylether;
Hexakis(methoxymethyl) melamine
Emergencies
Contacting CHEMTREC:
24 Hour Emergency Use Only #'s...
Worldwide phone: 1-(703)-527-3887
Worldwide FAX: 1-(703)-741-6090
Toll-free phone: 1-(800)-424-9300 USA only
Product or Trade Name.. SPI #02655-AB, 02655T-AB NanoplastŪ Resin
Synonyms............... MME 7002;
Non-plastified melamine resin;
Hexamethylolmelamine methyl ether;
Hexamethoxymethylmelamine;
N-hexamethylolmelamine hexamethylether;
Hexakis(methoxymethyl) melamine
| Hazardous
Material Information System USA | Health | 0 | National Fire Protection Association USA | ![]() |
| Fire Hazard | 1 | |||
| Reactivity | 0 | |||
| Personal Protection |
Component Name CAS # Percent EINECS/ELINCS Hexamethoxymethylmelamine 3089-11-0 >69% n/a Formaldehyde (in MME 7002) 50-00-0 <1% 200-001-8 Water 7732-18-5 30% 231-791-2
Emergency overview: Prolonged and continuous exposure may cause irritation. Appearance: Colorless aqueous solution Flash Point: n/a Potential Health Effects Eye: May cause eye irritation. Skin: May cause skin irritation. Ingestion: No data available. Inhalation: May cause respiratory tract irritation.
Eyes: In case of eye contact, flush eyes with water for at least 15 minutes. If irritation persists, seek medical attention. Skin: Wash thoroughly with soap and water after handling. If irritation persists, seed medical attention. Ingestion: Seek immediate medical attention. Inhalation: Remove to fresh air. If symptoms occur, seek immediate medical attention.
Flash Point: 100°C (DIN 53213)
Explosion Limits:
Upper: n/a
Lower: n/a
Autoignition Temperature: n/a
General Information:
In general, use the extinguishing media suitable for the surrounding
fire since realistically, this product is present only in small
quantities.
Extinguishing Media:
Water spray, foam, dry media, carbon dioxide
Hazardous Combustion Products:
Nitrogen compounds
General Information: Absorb with a wet cloth and place in special container for disposal. Spills/Leaks: Do not dispose of into sink, as product is water soluble.
Handling: Local ventilation, safety goggles, and protective gloves recommended. Storage: Store at room temperature.
Engineering Controls: Local ventilation recommended. Eye
wash station should be available to the work area.
Exposure Limits:
Chemical Name ACGIH NIOSH OSHA - Final PELs
CAS# 3089-11-0 n/a n/a n/a
CAS# 7732-18-5 n/a n/a n/a
CAS# 50-00-0 0.3 ppm TLV 0.016 ppm TWA 0.75 ppm TWA
.037 mg/m3 TLV 20 ppm IDHL 2 ppm STEL
0.5ppm Action Level
OSHA Vacated PELs:
CAS# 50-00-0: 3 ppm TWA
Personal Protective Equipment
Eyes: Chemical safety goggles recommended.
Skin: Protective gloves recommended.
Respirators:
Where conditions warrant use of a respirator, follow the OSHA
respirator regulations found in 29CFR 1910.134 or the European
Standard EN149. Always us a NIOSH or European Standard approved
respirator when necessary.
Physical State: Liquid Appearance: clear, colorless Odor: n/a pH: 8 Vapor Pressure: Not available Vapor Density: Not available Evaporation Rate: Not available Viscosity: Not available Boiling Point: Not available Freezing/Melting Point: Not available Autoignition Temperature: Not available Flash Point: 100°C (DIN 53213) Decomposition Temperature: Not available Explosion Limits: Lower: Not available Upper: Not available Solubility in water: miscible Specific Gravity/Density: 1.21 g/ml Molecular Formula: C15H30N6O6 Molecular Weight: 390
Chemical Stability: Stable Conditions to Avoid: Heat above 40°C Incompatibility with Other Materials: Polymerization initiators Hazardous Decomposition of Products: Nitrogen compounds Hazardous Polymerization: May occur
RTECS#:
CAS#: 3089-11-0 XZ1065000
CAS#: 50-00-0 LP8925000
CAS#: 7732-18-5 ZC0110000
LD50/LC50 Information:
CAS #:3089-11-0
Oryzias latipes LC50 = 680 mg/l
CAS #: 7732-18-5:
Oral, rat: LD50 = >90 ml/kg
CAS# 50-00-0:
Draize test, rabbit, eye: 750 ug Severe
Inhalation, mouse: LC50 = 505 gm/m3/2H
Inhalation, rat: LC50 = 578 gm/m3/2H
Carcinogenicity:
CAS# 3089-11-0:
Not listed by ACGIH, IARC, NTP, OR CA Prop 65
CAS# 7732-18-5:
Not listed by ACGIH, IARC, NTP, OR CA Prop 65
CAS# 50-00-0:
ACGIH: A2 - Suspected Human Carcinogen
California: Carcinogen, Initial date 1-1-88 (gas)
NTP: Suspect carcinogen
IARC: Group 1 carcinogen
Teratogenicity:
Exposure to Formaldehyde may cause birth defects.
Reproductive Effects:
Exposure to Formaldehyde may cause adverse reproductive effects and
birth defects. Adverse reproductive effects of Formaldehyde are
primarily based on animal studies. Very few human studies have
been done on the adverse reproductive effects from exposure to
Formaldehyde.
Neurotoxicity:
No data available.
Mutagenicity:
Exposure to Formaldehyde may affect genetic material.
Exotoxicity: No data available. Environmental Fate: No data available. Aquatic: No data available. Atmospheric: No data available. Physical: No data available.
RCRA P-Series: None listed.
RCRA U-Series:
CAS# 3089-11-0: Not listed.
CAS# 7732-18-5: Not listed.
CAS# 50-00-0: U122
Dispose of in accordance with all federal, state and local regulations.
US DOT Hazard Class: Not regulated. IATA (for international shipments) Not regulated.
United States:
TSCA
CAS# 3089-11-0 is listed on the TSCA Inventory
CAS# 7732-18-5: is listed on the TSCA Inventory.
CAS# 50-00-0 is listed on the TSCA Inventory.
Health & Safety Reporting List
None of the chemicals in this product are on the Health & Safety
Reporting List.
Chemical Test Rules
None of the chemicals in this product are under a Chemical Test Rule.
Section 12b:
None of the chemicals in this product are listed under TSCA Section 12b.
TSCA Significant New Use Rule:
None of the chemicals in this product has a SNUR under TSCA.
CERCLA:
CAS# 50-00-0: 100 lb final RQ, 45.4 kg final RQ
SARA:
Section 302 (TPQ)
CAS# 50-00-0: 500 lb TPQ
SARA Codes
CAS# 50-00-0: immediate, delayed
Section 313
This material contains Formaldehyde (CAS# 50-00-0) (36.5-38%)
which is subject to the reporting requirements of Section 313 of
SARA Title III and 40 CFR Part 373.
Clean Air Act:
CAS# 50-00-0 is listed as a hazardous air pollutant (HAP).
This product does not contain any Class 1 or Class 2 Ozone depletors.
Clean Water Act:
CAS# 50-00-0 IS LISTED AS A Hazardous Substance under the CWA.l
None of the chemicals in this product is listed as Priority Pollutant
or as Toxic Pollutant under the CWA.
OSHA:
CAS# 50-00-0 is considered highly hazardous by OSHA.
State (Individual states in the USA)
CAS# 50-00-0 is present on the California, Massachusetts, Minnesota,
New Jersey and Pennsylvania state lists.
California Prop. 65:
This product contains formaldehyde, which the State of California has
found to cause cancer and which would require a warning under state
statue.
European/International Regulations:
European Labeling in Accordance with EC Directives
Hazard Symbols: Xi Irritant
Risk Phrases:
R43: May cause sensitization by skin contact
Safety Phrases:
S26: Incase of contact with eyes, rinse immediately with plenty
of water and seek medical advice
S37: Wear suitable gloves
S38: Wear suitable eye/face protection
S51: Use only in well-ventilated areas
WGK (Water Danger/Protection):
CAS# 3089-11-0: no information available
CAS# 7732-18-5: no information available
CAS# 50-00-0: 2
Canada - DSL/NDSL
CAS# 3089-11-0 is on the DSL List
CAS# 7732-18-5 is listed on Canada's DSL List
CAS# 50-00-0 is listed on Canada's DSL List
WHMIS classification: B3
Disclaimer of Liability: Caution! Do not use SPI Supplies products or materials in applications involving implantation within the body; direct or indirect contact with the blood pathway; contact with bone, tissue, tissue fluid, or blood; or prolonged contact with mucous membranes. Products offered by SPI Supplies are not designed or manufactured for use in implantation in the human body or in contact with internal body fluids or tissues. SPI Supplies will not provide to customers making devices for such applications any notice, certification, or information necessary for such medical device use required by US FDA (Food and Drug Administration) regulation or any other statute. SPI Supplies and Structure Probe, Inc. make no representation, promise, express warranty or implied warranty concerning the suitability of these materials for use in implantation in the human body or in contact with internal body tissues of fluids. This product is intended for external contact only with human skin.
To Ask a Question or Make a Comment
To Place an Order or Request a Quote