SPI Supplies is the source! SPI Supplies Division
Structure Probe, Inc.

P.O. Box 656 West Chester, PA 19381-0656 USA
Phone: 1-(610)-436-5400 Fax: 1-(610)-436-5755
E-mail: spi3spi@2spi.com

WWW: http://www.2spi.com
Manufacturer's CAGE: 1P573

Material Safety Data Sheet

SPI#01841-AB, 01842-AB, 01843-AB, 01844-AB, and 01845-AB Magnesium Oxide Single Crystal Substrates


Section 01 Identification

Date Effective... January 8, 2009
                  (most recent revision)

Chemical Name/Synonyms:
Magnesium Oxide (MgO)

Chemical Family... Metal Oxide


Emergencies      Contacting CHEMTREC 24 Hour Emergency 
Use Only #'s.... Worldwide phone : 1-(703)-527-3887
                 Worldwide FAX   : 1-(703)-741-6090
                 Toll-free phone : 1-(800)-424-9300 USA only

Product or Trade Name... SPI Magnesium Oxide Single Crystal Substrates

CAS #....................  1309-48-4

Chemical Formula.........  MgO
Formula Weight........... 40.30 NFPA (National Fire Protection Association) Rating (Scale 0-4) : Not applicable


Section 02 Physical Data

Boiling Point............    760 mm Hg : 3600° C/6512° F

Coeff. of Water/Oil Dist.    Not Applicable

pH (Liquids Only)........    Not Applicable

% Volatile By Weight.....    N/A
% Volatile By Volume.....    3

Melting Point............    5166° F/2852° C

Vapor Pressure...........    mm Hg: Not Applicable

Vapor Density/Air is 1...    Not Applicable

Solubility In Water......    Less than 0.1%

Appearance and Color.....    Clear transparent solid; in powder form, it
                             becomes a white to gray looking free flowing
                             powder

Specific Gravity.........    (H2O = 1): 3.60

Evaporation Rate.........    (n-butyl acetate = 1): Zero

Odor.....................    None




Section 03 Fire And Explosion Hazard Data

Flash Point.................... Non-flammable

Flammable Limits in Air........ Flammable limit in air, % by vol.
  LEL (Lower Explosive Limit) : Not Applicable
  UEL (Upper Explosive Limit) : Not Applicable

Fire Extinguishing Media:
  This material is non-combustible.  Use appropriate extinguishing 
  agent for surrounding fires.  Do not use water to extinguish 
  fires around operations involving molten metal, due to the 
  potential for a steam explosion.

Firefighting Procedure:
  Appropriate for the surrounding fire

Fire and explosion hazards:
  This is a stable material and will not burn or ignite.

Toxic Gases Produced:  None



Section 04 Reactivity Data

Stable: Yes

Hazardous Polymerization:
   Does not occur
   
Hazardous Decomposition Products:
   None identified

Conditions to avoid:
   Air, dusting

Materials to avoid:
   Incompatibilities are with strong acids, bromine trifluoride and
   trichloride, phosphorus pentachloride



Section 05 Spill, Leak and Disposal Procedures

Spill Response:
   Not applicable for solid wafer products.

Disposal considerations:
   Should be done in accordance with all applicable federal, state, and
   local regulations.



Section 06 Health Hazard Data

Potential health effects (overview):

The material in either solid or alloy form is generally not considered
hazardous.  However, if the process involves grinding, melting, cutting, 
or any other process that causes a release of fumes, hazardous levels 
of airborne particulates could be generated.


Primary routes of entry:  
      Inhalation, Skin contact


Human effects and symptoms of exposure:
      Listed below are certain potential health hazards which apply to 
      the product in ground or powdered form:

      Inhalation:       Irritation of upper respiratory tract, leukocytosis
      Eye contact:      Irritation
      Ingestion:        None identified
      Skin contact:     Irritation
      Skin absorption:  None identified
      Chronic effects:  None identified


Threshold Limit Value:  10 mg/m3 of air (as Mg)
Short Term Exposure Limit:  (STEL):  Not established
Permissible Exposure Limit: (PEL):   15 mg/m3

Carcinogenicity:       None identified
Reproductive Effects:  None identified
Target organs:         Respiratory system, lungs, eyes


Medical Conditions Aggravated by Exposure:
      Respiratory system disease


Carcinogenic references:
      Material is not listed in the Annual Report on Carcinogens as 
      prepared by the National Toxicology Program (NTP), as well as 
      the International Agency for Research on Cancer (IARC), 
      Monograph Series or OSHA.


TLV (Units as Mg):  10 mg/m3 of air

Component          Weight %       OSHA/PEL     ACGIH/TLV

Magnesium oxide     99+%          15 mg/m3      10 mg/m3

SARA/Title III Hazard Categories and Lists:
Acute:         Yes
Chronic:       Yes
Flammability:  No
Pressure:      No
Reactivity:    No

Extremely Hazardous Substance:  No
CERCLA Hazardous Substance:     No
SARA 313 Toxic Chemicals:       No
TSCA:                           Yes



Section 07 First Aid Procedures And Physician Notes

The following information is provided in the event the solid wafer is cut
and powder and/or dust should be generated:

First Aid for Eyes:
     Dust or powder should be flushed from the eyes with running water 
     for 15 minutes. If irritation persists obtain medical assistance.

First Aid for Skin:
     Skin cuts and abrasions can be treated by standard first aid.  
     Skin contamination with dust or powder can be removed with soap 
     and water. If irritation persists obtain medical assistance.  Be
     sure to remove any contaminated clothing.

First Aid for Inhalation:
     Breathing difficulty, caused by inhalation of dust or fume 
     requires removal to fresh air.  If breathing has stopped 
     perform artificial respiration and seek medical assistance 
     at once.  If breathing is difficult, give oxygen.  But prompt
     action is essential!

First Aid for Ingestion:
     Obtain medical assistance at once.  If swallowed, do not induce
     vomiting.  If conscious, give large amounts of water.



Section 08 Special Handling Information


In the solid form of a wafer, this material poses no special problems. Store
metal in a dry area to extend shelf life.  Do not store adjacent to strong
acids or other items mentioned in "incompatibilities".



Section 09 Special Precautions and Additional Information

Eye Protection Requirements:
    Safety glasses are recommended especially if powder is being created.

Skin Protection Requirements:
    Protective gloves are recommended, to prevent mechanical 
    irritation.  This is particularly true if powder or dust
    is being generated.

Respiratory Protection:
    Use an appropriate NIOSH approved respirator if airborne 
    dust concentrations exceed the PEL or TLV.

Other protective equipment:
    Eye wash fountain should be readily available in areas of 
    use of handling especially if powder or dust is being created.

Exposure Limits:
    Not established for product as a whole.  Refer to Section 
    02 above.

Ventilation Requirements:
    Local exhaust:  Recommended, when cutting, grinding, or 
    melting or any other operation where dust or fumes are created.

Environmental Surveillance:
    If the operation generates dust or fumes, exposure to airborne 
    materials should be determined by having air samples taken in 
    the employee breathing zone and work area.



Section 10 Hazardous Ingredients


No hazardous ingredients in this material.



Section 11 Transportation Information

DOT Shipping Name:       Not regulated
DOT Hazard Class:        None
Product RQ:              None
Technical Shipping Name: Metal alloy
UN or NA number:         None



Section 12 Regulatory Information


OSHA Status:    N/A

TSCA Status:    These products are pure magnesium oxide (MgO).

RCRA Status:    N/A

SARA Title III: No hazardous substances.

California Prop. 65:
Proposition 65 requires manufacturers or distributors of consumer products
into the State of California to provide a warning statement if the product
contains ingredients for which the State has found to cause cancer, birth
defects or other reproductive harm.  If this product contains an ingredient
listed by the State of California to cause cancer or reproductive toxicity,
it will be listed below:


Section 13 Other Information

Disclaimer of Liability: Caution! Do not use SPI Supplies products or materials in applications involving implantation within the body; direct or indirect contact with the blood pathway; contact with bone, tissue, tissue fluid, or blood; or prolonged contact with mucous membranes. Products offered by SPI Supplies are not designed or manufactured for use in implantation in the human body or in contact with internal body fluids or tissues. SPI Supplies will not provide to customers making devices for such applications any notice, certification, or information necessary for such medical device use required by US FDA (Food and Drug Administration) regulation or any other statute. SPI Supplies and Structure Probe, Inc. make no representation, promise, express warranty or implied warranty concerning the suitability of these materials for use in implantation in the human body or in contact with internal body tissues of fluids.
************************************************************************
The information and recommendations set forth above are taken from sources believed to be accurate as of the date hereof, however SPI Supplies and Structure Probe, Inc. make no warranty with respect to the accuracy of the information or the suitability of the recommendations, and assume no liability to any user thereof. The information contained in this sheet does not constitute a hazard assessment and should not be used in place of the user's own assessment of work place risks as required by other health and safety legislation.

Be aware of the Structure Probe, Inc. Copyright Policy. Structure Probe, Inc. grants a nonexclusive license to make unlimited copies of this safety sheet for internal use only. Quite obviously, this information would pertain only to this material when purchased from SPI Supplies as product from other sources, with other ingredients and impurity levels could have substantially different properties.

To Ask a Question or Make a Comment

To Place an Order or Request a Quote


Return to:
Saturday March 20, 2010
© Copyright 1999 - . By Structure Probe, Inc.
Contacting SPI Supplies and Structure Probe, Inc.
All rights reserved.
All trademarks and trade names are the property of their respective owners.
Privacy Policy

Worldwide Distributors, Representatives, and Agents Flag logo