SPI #01813-BA, 01813-CF, 01813-MB SPI-Chem™ Silicon Monoxide (SiO) Chips




Section 1: Identification

Date Effective......... May 21, 2007
                        (most recent revision)

Chemical Name/Synonyms...  Silicon monoxide, silicon oxide                            

Emergencies                
Contacting CHEMTREC:

24 Hour Emergency Use Only #'s... 
Worldwide phone: 1-(703)-527-3887
Worldwide FAX:   1-(703)-741-6090 
Toll-free phone: 1-(800)-424-9300 USA only


Product or Trade Name....  Silicon monoxide chips

Chemical Family: Metal oxide

Formula: SiO


Hazardous Material
Information System
USA
Health 1 National Fire
Protection Association
USA
Fire Hazard 1
Reactivity 0
Personal Protection  
NFPA Rating: (estimated) Health: 1 ; Flammability: 1 ; Reactivity: 0

Section 2: Composition

Component Name          CAS #          Percent          EINECS/ELINCS
Silicon monoxide        10097-28-6     100%             233-232-8


Section 3: Hazard Identification

Appearance: Black solid

Flash Point: n/a 

Target Organs: May affect the respiratory system.

Potential Health Effects
To the best of our knowledge the chemical, physical and toxicological properties
of silicon monoxide have not been fully investigated.

Eye: May cause abrasive irritation, characterized by redness, itching and
watering.

Skin: May cause abrasive irritation, characterized by redness.

Ingestion: No acute health effects recorded.

Inhalation: May cause irritation to the respiratory system, characterized
by coughing, shortness of breath, wheezing, change in breathing capacity and
cyanosis.

Chronic: Chronic inhalation may cause pneumoconiosis, pulmonary fibrosis
and silicosis.


Section 4: First Aid Measures

Eyes: Flush eyes with lukewarm water, lifting eyelids, for at least 15
minutes.  Seek medical attention if symptoms persist.

Skin: remove contaminated clothing. Brush material off skin and wash
affected area with mild soap and water.  Seek medical attention if symptoms
persist.

Ingestion: No acute or chronic health effects are known by ingestion. 

Inhalation: Remove victim to fresh air. Give oxygen if breathing is
difficult.  Seek medical attention if symptoms persist.


Section 5: Fire Fighting Measures

General Information:
Silicon monoxide may emit toxic fumes if involved in a fire. May be flammable
and possibly pyrophoric on contact with air at extremely elevated temperatures.
Fire fighters must wear full face, self-contained breathing apparatus with full
protective clothing to prevent contact with skin and eyes. Fumes from fire are
hazardous. Isolate runoff to prevent environmental pollution.

Extinguishing Media:
Not applicable. Use suitable extinguishing media for surrounding materials and
type of fire.


Section 6: Accidental Release Measures

General Information:
Wear appropriate respiratory and protective equipment.

Spills/Leaks:
Isolate spill area. Provide ventilation. Vacuum up spill using high efficiency
particulate absolute (HEPA) air filter and place in a closed container for proper
disposal.  Do not raise dust. Dispose of in accordance with all federal, state
and local regulations.


Section 7: Handling and Storage

Handling:
Wash thoroughly after handling. 

Storage:
Store in cool, dry area in tightly closed containers.

Section 8: Exposure Controls and Personal Protection

Engineering Controls:
Use local exhaust to maintain concentration at low exposure levels.

Exposure Limits: 

No exposure limits listed for ACGIH, NIOSH, OSHA.

OSHA:
Component		PerCent		TLV		PEL
Silicon monoxide	100%		10 mg/m3	15 mg/m3
					(total dust)	(total dust)
		
Personal Protective Equipment

Eyes: Safety glasses

Skin: Impervious gloves

Clothing: Suitable to prevent skin contact

Respirators: NIOSH approved respirator.


Section 9: Physical and Chemical Properties

Physical State:  solid
Appearance:  black
Odor:  none
pH:  n/a
Vapor Pressure: n/a 
Vapor Density: n/a
Evaporation Rate: n/a 
Viscosity: n/a 
Boiling Point:  1880°C (3416.0°F)
Freezing/Melting Point: 1702.0°C (3095.6°F)  
Autoignition Temperature:  n/a
Flash Point:  n/a
Decomposition Temperature:  n/a
Explosion Limits:
	Lower:  n/a
	Upper:  n/a
Solubility in water: insoluble 
Specific Gravity/Density:  2.13 (water=1)
Molecular Formula: SiO 
Molecular Weight:  44.08

n/a = not available


Section 10: Stability and Reactivity

Chemical Stability:
Stable

Conditions to Avoid:
None

Incompatibility with Other Materials:
Strong acids and bases

Hazardous Decomposition of Products:
Silicon dioxide

Hazardous Polymerization:
Will not occur


Section 11: Toxicological Information

RTECS#:
n/a

LD50/LC50 Information: n/a

CAS# 10097-28-6 is not listed by ACGIH, NIOSH, NTP, IARC and is not listed by
California Prop 65 as a known carcinogen.  

Teratogenicity: n/a

Reproductive Effects: n/a

Neurotoxicity:  n/a

Mutagenicity: n/a

Other Studies:  n/a


Section 12: Ecological Information

No data available.

Section 13: Disposal Considerations

RCRA P-Series:  none
RCRA U-Series:  none

Dispose of in accordance with all federal, state and local regulations.

Section 14: Transport Information

US DOT Hazard Class:
Not hazardous from the standpoint of shipping.

IATA (for international shipments):
Not hazardous from the standpoint of shipping.

Section 15: Regulatory Information

United States:

TSCA
CAS# 10097-28-6 is listed on the TSCA Inventory.

Health & Safety Reporting List
CAS# 10097-28-6 is not on the Health & Safety Reporting List.

Chemical Test Rules
CAS# 10097-28-6 does not have a Chemical Test Rule.

Section 12b:
CAS# 10097-28-6 is not listed under TSCA Section 12b.

TSCA Significant New Use Rule:
CAS# 10097-28-6 does not have a SNUR.

CERCLA Section 103:
CAS# 10097-28-6 is not listed under CERCLA Section 103.

SARA:
CAS# 10097-28-6 is not listed under SARA.

State (Individual states in the USA)
CAS# 10097-28-6 not listed.

California No Significant Risk Level: 
CAS# 10097-28-6 not listed.

California Prop. 65:
CAS# 10097-28-6 not listed.
  

European/International Regulations:
European Labeling in Accordance with EC Directives

Hazard Symbols: Xn  Harmful
Risk Phrases:       
	R20  Harmful by inhalation      
Safety Phrases:
	S29  Do not empty into drains
	S36  Wear suitable protective clothing


WGK (Water Danger/Protection):
Not available.
 
Canada

WHMIS
This product has been classified in accordance with the hazard criteria of
the CPR, and the MSDS contains all the information required by the CPR.
 

DSL/NDSL 
CAS# 10097-28-6 is listed on the NDSL List.

Section 16: Other Information

Disclaimer of Liability:

Caution! Do not use SPI Supplies products or materials in applications involving implantation within the body; direct or indirect contact with the blood pathway; contact with bone, tissue, tissue fluid, or blood; or prolonged contact with mucous membranes. Products offered by SPI Supplies are not designed or manufactured for use in implantation in the human body or in contact with internal body fluids or tissues. SPI Supplies will not provide to customers making devices for such applications any notice, certification, or information necessary for such medical device use required by US FDA (Food and Drug Administration) regulation or any other statute. SPI Supplies and Structure Probe, Inc. make no representation, promise, express warranty or implied warranty concerning the suitability of these materials for use in implantation in the human body or in contact with internal body tissues of fluids.

************************************************************************

The information and recommendations set forth above are taken from sources believed to be accurate as of the date hereof, however SPI Supplies and Structure Probe, Inc. make no warranty with respect to the accuracy of the information or the suitability of the recommendations, and assume no liability to any user thereof. The information contained in this sheet does not constitute a hazard assessment and should not be used in place of the user's own assessment of work place risks as required by other health and safety legislation.

Be aware of the Structure Probe, Inc. Copyright Policy. Structure Probe, Inc. grants a nonexclusive license to make unlimited copies of this safety sheet for internal use only. Quite obviously, this information would pertain only to this material when purchased from SPI Supplies or SPI authorized agents and distributors, and in original SPI Supplies packaging, as product from other sources, with other ingredients and impurity levels could have substantially different properties.


To Ask a Question or Make a Comment

To Place an Order or Request a Quote


Return to:
Monday December 01, 2008
© Copyright 2007 - 2008. Structure Probe, Inc
Contacting SPI Supplies and Structure Probe, Inc.
All rights reserved.
All trademarks and trade names are the property of their respective owners.
Privacy Policy

Worldwide Distributors, Representatives, and Agents Flag logo