SPI Supplies Division
Date Effective......... May 22, 2007
(most recent revision)
Chemical Name/Synonyms: Carbon Black Filled Conductive Epoxy Resin
Chemical Family........ Epoxy Resin
Synonyms............... none
Emergencies Contacting CHEMTREC 24 Hour Emergency
Use Only #'s.... Worldwide phone : 1-(703)-527-3887
Worldwide FAX : 1-(703)-741-6090
Toll-free phone : 1-(800)-424-9300 USA only
|
Hazardous Material Information System USA |
Health | 2 |
National Fire Protection Association USA |
|
| Fire Hazard | 1 | |||
| Reactivity | 0 | |||
| Personal Protection |
Component Name CAS # Percent EC # Epoxy Resin Proprietary N/A N/A Alkyl Glycidyl Ether Proprietary N/A N/A Natural graphite 7782-42-5 N/A 231-955-3 Carbon Black 1333-86-4 N/A 215-609-9 N/A = not available
Emergency overview May cause eye, skin, and respiratory irritation. May cause skin sensitization. Flash point: 302° F (cc) Potential Health Effects Eye: May be irritating to eyes. Skin: May be irritating to skin. May cause rash, itching, or dermititis. May cause skin sensitization. Ingestion: May cause irritation of throat, mouth, or gastrointestinal tract. May cause diarrhea or nausea. Inhalation: May cause respiratory tract irritation if inhaled. Chronic: May cause skin sensitization, rash or dermititis.
Eyes: In case of eye contact, flush with copious amounts of water for at least 15 minutes holding the eyes open. Seek medical attention. Skin: In case of skin contact, flush with copious amounts of water. Remove contaminated clothing and wash before reuse. If irritation develops, seek medical attention. Ingestion: Adverse health effects due to ingestion are not anticipated. If gastric irritation or discomfort persists, seek medical advice. Inhalation: If symptoms are experienced, move victim to fresh air, if symptoms persist, obtain medical attention. Notes to Physician: Treat supportively and symptomatically.
Flash Point: 302° F (cc)
Explosion Limits:
Upper: N/A
Lower: N/A
Autoignition Temperature: N/A
General Information: Wear full protective equipment including self
containing breathing apparatus.
Extinguishing Media: Carbon dioxide, foam, or dry chemical.
Hazardous Combustion Products: Carbon monoxide, carbon dioxide, phenolics.
Release response:
Absorb with inert material. Vacuum or otherwise pick up and retain for
recycle or disposal. Do not flush spilled material to the sewer or the
environment. Avoid creating a dust cloud since this could create an a
potential for a dust explosion hazard. Use vacuum equipment designed
especially for handling combustible dust.
Handling: Avoid contact with eyes, skin, or clothing. Keep away from food and drink. Storage: Store in closed containers in cool dry area.
Engineering Controls: Forced air ventilation. Safety shower and eye wash
station required in work area.
Exposure Limits:
Chemical Name ACGIH OSHA - Final PELs
Epoxy Resin N/A N/A
Alkyl Glycidyl Ether N/A N/A
Natural graphite 2.0 mg/m3 TWA N/A
Carbon black 3.5 mg/m3 TWA 3.5 mg/m3 TWA
OSHA Vacated PELs: N/A
Personal Protective Equipment: Engineering Controls:
If user operations generate dust or fumes, ventilate area to
prevent accumulation.
Personal Protection:
Inhalation: Use appropriate respiratory protection where
atmosphere exceeds recommended limits.
Skin: Protective clothing such as long sleeves or a lab
coat should be worn. When handling heated materials,
also be sure to use heat-resistant gloves, boots and
face protection. Such precautions are of course not
necessary for the use of small quantities such as in
an electron microscope laboratory. Neoprene or nitrile gloves
recommended.
Eye: Always use safety glasses, even for work with small
quantities, such as the making Formvar filmed grids.
Hygienic Practices: Wash thoroughly after using and before eating, drinking,
smoking, or using the restroom. Remove and launder contaminated clothing.
Physical State: N/A
Appearance: Black, tar-like
Odor: N/A
pH: N/A
Vapor Pressure: N/A
Vapor Density: N/A
Evaporation Rate: N/A
VOC (excluding H2O and exempts): 0.0
Viscosity: N/A
Boiling Point: N/A
Freezing/Melting Point: N/A
Autoignition Temperature: N/A
Flash Point: 302° F
Decomposition Temperature: N/A
Explosion Limits:
Lower: N/A
Upper: N/A
Solubility in water: N/A
Solubility in organic solvent: N/A
Specific Gravity/Density: 1.2178
Molecular Formula: N/A
Molecular Weight: N/A
Chemical Stability: Stable Conditions to Avoid: Excessive heat. Incompatibility with Other Materials: Strong acids, amines, mercaptans, and bases. Hazardous Decomposition of Products: Carbon monoxide, carbon dioxide, phenolics. Hazardous Polymerization: Will not occur.
The full toxicological properties of this product have not been determined.
The full ecological properties of this product have not been determined.
This product is not a "hazardous waste" as that term is defined in the Resource Conservation and Recovery Act (RCRA), 40 DFR 261, "Identification and Listing of Hazardous Waste". Burn in an approved incinerator or dispose of in an approved landfill in accordance with all applicable local, state, and federal laws and regulations. Consult your appropriate regulatory officials for information on such disposal.
US DOT Hazard Class: Not hazardous for transport. IATA (for international shipments): Not hazardous for transport.
United States:
TSCA
All components of this product are listed on the TSCA Inventory List.
OSHA:
This product is not considered by OSHA to be highly hazardous.
State (Individual states in the USA)
This product does not contain any components listed on any state list.
California No Significant Risk Level:
California Prop. 65:
CAS # 1333-86-4 is listed under California Prop. 65 as a possible carcinogen.
European:
Hazard Symbols: N/A
Risk Phrases:
R36/37/38 Irritating to eyes, respiratory system, and skin.
R43 May cause sensitization by skin contact.
Safety Phrases:
S2 Keep out of reach of children.
S3/7 Keep container tightly closed in a cool place.
S24/25 Avoid contact with skin and eyes.
Canada
WHMIS: N/A
DSL/NDSL:
CAS # 7782-42-5 is on the DSL List
CAS # 1333-86-4 is on the DSL List
Disclaimer of Liability:
Caution! Do not use SPI Supplies products or materials in applications involving implantation within the body; direct or indirect contact with the blood pathway; contact with bone, tissue, tissue fluid, or blood; or prolonged contact with mucous membranes. Products offered by SPI Supplies are not designed or manufactured for use in implantation in the human body or in contact with internal body fluids or tissues. SPI Supplies will not provide to customers making devices for such applications any notice, certification, or information necessary for such medical device use required by US FDA (Food and Drug Administration) regulation or any other statute. SPI Supplies and Structure Probe, Inc. make no representation, promise, express warranty or implied warranty concerning the suitability of these materials for use in implantation in the human body or in contact with internal body tissues of fluids.
The information and recommendations set forth above are taken from sources believed to be accurate as of the date hereof, however SPI Supplies and Structure Probe, Inc. make no warranty with respect to the accuracy of the information or the suitability of the recommendations, and assume no liability to any user thereof. The information contained in this sheet does not constitute a hazard assessment and should not be used in place of the user's own assessment of work place risks as required by other health and safety legislation.
Be aware of the Structure Probe, Inc. Copyright Policy. Structure Probe, Inc. grants a nonexclusive license to make unlimited copies of this safety sheet for internal use only. Quite obviously, this information would pertain only to this material when purchased from SPI Supplies or SPI authorized agents and distributors, and in original SPI Supplies packaging, as product from other sources, with other ingredients and impurity levels could have substantially different properties.
To Ask a Question or Make a Comment
To Place an Order or Request a Quote