SPI #00031-MB, 00013-RA, 00031-XP, 00031-XK, Octoil®-S Dioctylsebacate Diffusion Pump Fluid




Octoil®-S Dioctylsebacate Diffusion

Section 1: Identification

Date Effective........... September 29, 2011
                          (most recent revision)

Chemical Name/Synonyms... Octoil®-S Dioctylsebacate Diffusion Pump Fluid
                          Di-2-ethylhexyl sebacate

Emergencies                
Contacting CHEMTREC:

24 Hour Emergency Use Only #'s... 
Worldwide phone: 1-(703)-527-3887
Worldwide FAX:   1-(703)-741-6090 
Toll-free phone: 1-(800)-424-9300 USA only


Product or Trade Name.... SPI #00031-MB, 00031-RA, 00031-XP, 00031-XK
                          Octoil®-S Dioctylsebacate Diffusion Pump Fluid
Synonyms................. Di-2-ethylhexyl sebacate

Chemical Formula......... (C8H17)-OOC-(C8H17)COO-(C8H17)
 
Hazardous Material
Information System
USA
Health 1 National Fire
Protection Association
USA
Fire Hazard 1
Reactivity 1
Personal Protection  
NFPA Rating: (estimated) Health: 1 ; Flammability: 1 ; Reactivity: 1 Special: none

Section 2: Composition

Component Name            CAS #          Percent       EINECS/ELINCS
Di-2-ethylhexyl sebacate  122-62-3       ~100          204-558-8

Section 3: Hazard Identification

Emergency overview:
May cause slight eye irritation. May cause skin irritation. May be harmful 
if swallowed.

Appearance: Colorless liquid

Flash Point: >215°C  (Cleveland Open Cup)   
 
Target Organs: Unknown

Potential Health Effects

Eye: May cause slight eye irritation

Skin: Prolonged or repeated skin contact may produce skin irritation

Ingestion: May be harmful by ingestion. May cause irritation to mouth,
throat, and stomach.

Inhalation: Inhalation may cause dizziness

Chronic: Unknown



Section 4: First Aid Measures

Eyes: Flush with copious amounts of water for at least 15 minutes.  
Seek medical attention.

Skin: Wash affectd area with plenty of soap and water.  Seek medical
attention if symptoms occur.

Ingestion: Seek medical attention!

Inhalation: Move victim to fresh air.

Notes to Physician: Treat symptomatically and supportively.


Section 5: Fire Fighting Measures

General Information:
Wear a MESA/NIOSH approved positive pressure self-contained breathing
apparatus and firefighter turnout gear.

Extinguishing Media:
Use Water fog, chemical foam or carbon dioxide. NFPA Class II B Material.  Water may cause frothing.

Flash Point: >215°C  (Cleveland Open Cup)

Explosion Limits
     Lower: Unknown
     Upper: Unknown

Section 6: Accidental Release Measures

General Information:
Wash affected skin areas with soap and water. Prevent spill from entering
seweres and open bodies of water.

Spills/Leaks:
Contain spill by diking with inert material, such as sand, earth, etc.
Transfer spilled liquid and diking material to separate containers for
disposal or recovery.  Wash floor area with hot water solution of OAKITE or
equivalent.

Section 7: Handling and Storage

Handling:
Establish and maintain safe operating procedures if this product is to be
used in an elevated process.

Storage:
Store in tightly closed containers in cool, dry well-ventilated storage area
away from all oxidizing materials.

Section 8: Exposure Controls and Personal Protection

Engineering Controls:
Local exhaust for room temperature operations.  Direct exhaust for operations
carried out at elevated temperatures. Eyewash station available to work area.

Exposure Limits:

Chemical Name           ACGIH   NIOSH   OSHA - Final PELs
Di-2-ethylhexyl sebacate n/a     n/a     n/a

OSHA Vacated PELs: n/a

n/a= not available

Personal Protective Equipment

Eyes: Chemical safety glasses with side shields

Skin: Impermeable gloves

Clothing: Wear an apron or coveralls if exposure is likely 
to be prolonged.

Respirators: Not required for normal operations.


Section 9: Physical and Chemical Properties

Physical State: Liquid
Appearance: Colorless
Odor: Faint
pH: Not availabe
Vapor Pressure: .1 Torr @150°C
Vapor Density: Not available
Evaporation Rate: Nil (ether = 1)
Viscosity: Not available
Boiling Point:450-480°C at 4 mm
Freezing/Melting Point: Not available
Autoignition Temperature: Not available
Flash Point: >215°C
Decomposition Temperature: Not available
Explosion Limits:
        Lower: Not available
        Upper: Not available
Solubility in water: 0.01 gm/Liter
Specific Gravity/Density: 0.912
Molecular Formula:(C8H17)-OOC-(C8H17)COO-(C8H17) 
Molecular Weight: Not available



Section 10: Stability and Reactivity

Chemical Stability:
Stable under normal conditions

Conditions to Avoid:
High temperatures

Incompatibility with Other Materials:
Strong oxidizers

Hazardous Decomposition of Products:
Will not occur under normal circumstances

Hazardous Polymerization:
Not known

Section 11: Toxicological Information

RTECS#:
CAS# 122-62-3: VS1000000

LD50/LC50 Information:
           LD50          Rat, oral          > 5 g/kg
           LD50          Mouse, oral        9500 mg/kg
           LD50          Rabbit, dermal     > 2 g/kg
           Irritancy     Rabbit, eye        not an irritant
           Irritancy     Rabbit, skin       not an irritant or corrosive
 
Carcinogenicity: Not available
ACGIH: Not available
California: Not available
NIOSH: Not available
NTP: Not available
OSHA: Not available
IARC: Not available

Teratogenicity: Not available

Reproductive Effects: Not available

Neurotoxicity: Not available

Mutagenicity: Not available

Other Studies: Not available



Section 12: Ecological Information

Exotoxicity:
Not available

Environmental Fate:
Not available

Aquatic:
          LC50          Daphnia magna          >1000 mg/Liter

Atmospheric:
This product does not contain any ozone depleting materials.

Physical:
Not available



Section 13: Disposal Considerations

RCRA P-Series: Not available
RCRA U-Series: Not available

Use a licensed, approved waste disposal service.  Incinerate liquid 
in approved equipment.  Dispose of contaminated diking material in
a approved landfill.  Dispose of in accordance with all federal, state
and local environmental regulations.


Section 14: Transport Information

US DOT Hazard Class: Not hazardous for transport

IATA (for international shipments): Not hazardous for transport


Section 15: Regulatory Information

United States:

TSCA
This product is listed on the TSCA Inventory.

Health & Safety Reporting List Not available

Chemical Test Rules Not available

Section 12b: Not available

TSCA Significant New Use Rule: Not available

CERCLA Section 103: Not available

SARA:
This product contains no chemicals that require reporting to SARA Section 313.
This product contains no chemicals that require reporting to SARA Title III.
This product contains no chemicals that require reporting to 40 CFR Part 372.

OSHA:
This product contains no chemicals considered to be hazardous by OSHA>

State (Individual states in the USA) 
CAS# 122-62-3 is not listed on the CA, Fl, MA, MN, NJ, or PA state lists.

California No Significant Risk Level:

California Prop. 65: 
This product contains no chemicals listed under California Prop. 65.

  

European/International Regulations:
European Labeling in Accordance with EC Directives

Hazard Symbols:
This product is not classified.

Risk Phrases:        
     R      
     

Safety Phrases:
     S 2  Keep out of reach of children
     S 24/25 Avoid contact with skin and eyes


WGK (Water Danger/Protection): 
CAS# 122-62-3: 1


Canada

This product has a WHMIS classification of: Not available

DSL/NDSL
 CAS# 122-62-3 is listed on the DSL List.
 CAS# 122-62-3 is not listed on the NDSL List.




Section 16: Other Information

If this product should be used in ways that are outside of the intended applications in scanning electron microscope laboratories, and if it is going to be formulated into some other system, so that it becomes just another component of that other system, read the MSDS sheets for the other components before blending as the resulting mixture may have the hazards of all of its parts.

Disclaimer of Liability:

Caution! Do not use SPI Supplies products or materials in applications involving implantation within the body; direct or indirect contact with the blood pathway; contact with bone, tissue, tissue fluid, or blood; or prolonged contact with mucous membranes. Products offered by SPI Supplies are not designed or manufactured for use in implantation in the human body or in contact with internal body fluids or tissues. SPI Supplies will not provide to customers making devices for such applications any notice, certification, or information necessary for such medical device use required by US FDA (Food and Drug Administration) regulation or any other statute.

SPI Supplies and Structure Probe, Inc. make no representation, promise, express warranty or implied warranty concerning the suitability of these materials for use in implantation in the human body or in contact with internal body tissues of fluids.

************************************************************************

The information and recommendations set forth above are taken from sources believed to be accurate as of the date hereof, however SPI Supplies and Structure Probe, Inc. make no warranty with respect to the accuracy of the information or the suitability of the recommendations, and assume no liability to any user thereof. The information contained in this sheet does not constitute a hazard assessment and should not be used in place of the user's own assessment of work place risks as required by other health and safety legislation. Be aware of the Structure Probe, Inc. Copyright Policy. Structure Probe, Inc. grants a nonexclusive license to make unlimited copies of this safety sheet for internal use only. Quite obviously, this information would pertain only to this material when purchased from SPI Supplies as product from other sources, with other ingredients and impurity levels could have substantially different properties.


To Ask a Question or Make a Comment

To Place an Order or Request a Quote


Return to:
Tuesday May 22, 2012
© Copyright 2007 - 2012. Structure Probe, Inc
Contacting SPI Supplies and Structure Probe, Inc.
All rights reserved.
All trademarks and trade names are the property of their respective owners.
Privacy Policy

Worldwide Distributors, Representatives, and Agents Flag logo