SPI Supplies Division
|
Date Effective......... February 17, 2007
(most recent revision)
Chemical Name/Synonyms. 100% five ring polyphenyl ether
Chemical Family........ Not known
Emergencies Contacting CHEMTREC 24 Hour Emergency
Use Only #'s.... Worldwide phone : 1-(703)-527-3887
Worldwide FAX : 1-(703)-741-6090
Toll-free phone : 1-(800)-424-9300 USA only
Product or Trade Name.... SPI #00012-MB and #00012-RA Santovac 5 Polyphenyl
Ether Diffusion Pump Fluid
CAS #.................... 2455-71-2
Chemical Formula......... Not known
CAS #.................... 2455-71-2 This product is not a hazardous chemical(s) under the criteria of the OSHA Hazard Communication Standard (29 CFR 1910.1200).
Emergency overview: Appearance and Odor: light yellow essentially clear liquid with no odor to slight phenolic odor NO SIGNIFICANT HAZARDS ASSOCIATED WITH THIS MATERIAL POTENTIAL HEALTH EFFECTS Likely Routes of Exposure: skin contact Occupational exposure to this material has not been reported to cause significant adverse health effects. On the basis of available information, exposure to Santovac 5 vacuum pump fluid is not expected to produce significant adverse human health effects when recommended safety precautions are followed. Refer to Section 11 for toxicological information.
IF IN EYES OR ON SKIN, immediate first aid is not likely to be required. However, this material can be removed with water. Wash heavily contaminated clothing before reuse. IF INHALED, immediate first aid is not likely to be required. However, if symptoms occur, remove to fresh air. Remove material from eyes, skin and clothing. IF SWALLOWED, immediate first aid is not likely to be required. A physician or Poison Control Center can be contacted for advice.
Flash Point: 550° F (287° C) Method: Cleveland Open Cup Autoignition Temperature: 1135° F (612° C) Fire Point: 660° F (348° C) Extinguishing Media: In case of fire, use water spray (fog), foam, dry chemical, or C02 Unusual Fire and Explosion Hazards: None known Fire Fighting Equipment: Fire fighters and others exposed to products of combustion should wear self-contained breathing apparatus. Fire fighting equipment should be thoroughly decontaminated after use.
Contain large spills with dikes and transfer the material to appropriate containers for reclamation or disposal. Absorb remaining material or small spills with an inert material and then place in a chemical waste container. Flush residual spill area with water. Refer to Section 13 for disposal information and, Section 15 for reportable quantity information.
HANDLE IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE AND SAFETY PRACTICES. THESE PRACTICES INCLUDE AVOIDING UNNECESSARY EXPOSURE AND REMOVAL OF MATERIAL FROM EYES, SKIN AND CLOTHING. Emptied container retains vapor and product residue. Observe all labeled safeguards until container is cleaned, reconditioned, or destroyed. Storage: Product is stable under normal conditions of storage and handling.
Eye Protection: This product does not cause significant eye irritation or
eye toxicity requiring special protection. Use good industrial practice
to avoid eye contact.
Skin Protection: Although it does not present a significant skin concern,
minimize skin contamination by following good industrial practice. Wearing
protective gloves is recommended. Wash hands and contaminated skin
thoroughly after handling.
Respiratory Protection: Avoid breathing mist. Use NIOSH/MSHA approved
respiratory protection equipment when airborne exposure is excessive.
Consult respirator manufacturer to determine appropriate type equipment
for given application. Observe respirator use limitations specified by
NIOSH/MSHA or the manufacturer. Respiratory protection programs must
comply with 29 CFR 1910.134.
Ventilation: Provide natural or mechanical ventilation to minimize
exposure. If practical, use local mechanical exhaust ventilation at
sources of air contamination such as open process equipment.
Airborne Exposure Limits:
Product: Santovac 5 vacuum pump fluid
OSHA PEL: None Established
ACGIH TLV: None Established
Appearance: light yellow essentially clear liquid Odor: odorless to slight phenolic Boiling Point @ 760 mm Hg: = 889° F (476° C) Pour Point = 40° F (5° C) Specific Gravity @ 25/25° C: 1.195-1.201 pH: Neutral Vapor Density (Air = 1): 15.5 Solubility: Soluble in acetone and light aromatic solvents; insoluble in water NOTE: These physical data are typical values based on material tested but may vary from sample to sample. Typical values should not be construed as a guaranteed analysis of any specific lot or as specifications for the product.
Product is stable under normal storage and handling conditions. Materials to Avoid: Exposure to highly oxidizing agents should be avoided. Hazardous Decomposition Products: Continued use at temperatures above 425° C may result in the formation of benzene and phenol. If the product is burned, complete combustion produces carbon dioxide and water; incomplete combustion produces carbon monoxide (CO), smoke, soot, and lower molecular weight hydrocarbons. Hazardous Polymerization: Does not occur
Data from laboratory studies conducted by Monsanto with Santovac 5 vacuum Pump fluid are summarized below. Single exposure (acute) studies indicate: Oral: Practically Nontoxic (Rat LD50 >10,000 mg/kg) Dermal: Practically Nontoxic (Rabbit LD50 >5,000 mg/kg) Eye Irritation: Practically Nonirritating (Rabbit, 0.1/110.0) Skin Irritation:Practically Nonirritating (Rabbit, 24-hr exposure, 0.4/8.0) In a controlled skin contact study, no skin irritation (primary or cumulative) or skin allergy was observed in humans following repeated exposures to a polyphenyl ether formulation similar to Santovac 5 vacuum pump fluid. Increases in liver weights and liver/body weight ratios with accompanying increase in liver cell size, considered to be related to increased liver metabolic activity and increases in adrenal weight were noted in rats following repeated skin exposure (4-weeks). Santovac 5 vacuum pump fluid has produced no genetic changes in standard tests using animal or bacterial cells.
Exotoxicity: No information found in our select references. Environmental Fate: No information found in our selected references. Bioaccumulation: No information found in our select references.
Product to be disposed of, spilled liquid product, or spills absorbed on a solid medium may be classified as "hazardous waste" (DO18) due to the presence of benzene over 0.5 mg/L. Waste should be analyzed in accordance with Method 1311 Toxicity Characteristic Leaching Procedure (TCLP) and/or compared to the criteria of 40 CFR 261.24 to insure proper disposal. Waste product may also be classified as waste oil under state and federal regulations. Any discarded product, whether "hazardous waste" or not, should be incinerated in accordance with all local, state, or federal laws and regulations. Consult your attorney or appropriate regulatory officials for information on such disposal.
The data provided in this section is for information only. Please apply the appropriate regulations to properly classify your shipment for transportation. This product is not hazardous under the applicable DOT, ICAO/IATA, or IMDG regulations.
TSCA Inventory: All components are listed. SARA Hazard Notification Hazard Categories Under Title III Rules (40 CFR 370): Not Applicable Section 313 Toxic Chemical(s): Not Applicable CERCLA Reportable Quantity: Not Applicable Refer to Section 2 for OSHA Hazardous Chemical(s) and Section 13 for RCRA classification. California Prop. 65: Proposition 65 requires manufacturers or distributors of consumer products into the State of California to provide a warning statement if the product contains ingredients for which the State has found to cause cancer, birth defects or other reproductive harm. If this product contains an ingredient listed by the State of California to cause cancer or reproductive toxicity, it will be listed below: No data has been generated to our knowledge whether this material has been found to cause cancer, birth defects or other reproductive harm. Therefore, to be on the safe side, we would advice treating this product as if it does have those properties and respond accordingly.
Disclaimer of Liability: Caution! Do not use SPI Supplies products or materials in applications involving implantation within the body; direct or indirect contact with the blood pathway; contact with bone, tissue, tissue fluid, or blood; or prolonged contact with mucous membranes. Products offered by SPI Supplies are not designed or manufactured for use in implantation in the human body or in contact with internal body fluids or tissues. SPI Supplies will not provide to customers making devices for such applications any notice, certification, or information necessary for such medical device use required by US FDA (Food and Drug Administration) regulation or any other statute. SPI Supplies and Structure Probe, Inc. make no representation, promise, express warranty or implied warranty concerning the suitability of these materials for use in implantation in the human body or in contact with internal body tissues of fluids.********************************************************************** The information and recommendations set forth above are taken from sources believed to be accurate as of the date hereof, however SPI Supplies and Structure Probe, Inc. make no warranty with respect to the accuracy of the information or the suitability of the recommendations, and assume no liability to any user thereof. The information contained in this sheet does not constitute a hazard assessment and should not be used in place of the user's own assessment of work place risks as required by other health and safety legislation. Be aware of the Structure Probe, Inc. Copyright Policy. Structure Probe, Inc. grants a nonexclusive license to make unlimited copies of this safety sheet for internal use only. Quite obviously, this information would pertain only to this material when purchased from SPI Supplies as product from other sources, with other ingredients and impurity levels could have substantially different properties.
To Ask a Question or Make a Comment