SPI Supplies® TEM Grid Collection

Why some grids are more likely to require cleaning before use



Chinese




We wish to share some information about the grid making process that is not generally known, however, we release it here in order to minimize the "cleaning" of grids that really don't have to be cleaned at all!

Quite simply put, the copper grids offered by SPI Supplies are passivated with a passivation layer, it is a proprietary anti-tarnishing treatment of primarily organic composition. The amount of layer present is measured in terms of molecular dimensions, and its presence should be detectable only with XPS or Auger.

Such passivation coatings to reduce or eliminate tarnishing (e.g. oxidation) of the grid surface is not necessary and therefore is not applied to the grids made from Ni or Au.

The vast majority of users of copper grids find no real need to "clean" this passivation layer from the surfaces of their grids before use. However, there are some who have found that this extra cleaning step does result in better results. So clearly, there could be reasons for the cleaning of copper grids before use.

To the degree we can determine, at least some of those engaging in this cleaning process picked up and carried over the cleaning step from a time that they were using copper grids. But for most users of the SPI nickel or gold grids, such a cleaning step really is not necessary. The final cleaning step given the SPI grids should render such further cleaning unnecessary.

Cleaning to improve adhesion:
Some users report better section adhesion to grids that have been cleaned. However, the way one picks up their sections on the grids can have an even far greater impact on section adhesion to a grid. Putting it another way, you want to take full advantage of surface tension effects to hold the sections to your grids, thereby avoiding the use of so-called "grid pens". If the sections are picked up from underneath, that is, the grid is lowered into the water first, and the approach to the section is from underneath, there will be experienced maximum surface tension forces holding the section in place on the grid. Those who approach the grid from above, pushing the grid down on the section, seem to experience less of the surface tension forces, perhaps because the grid never really was completely wet by the water.

But if you think that your grids should be cleaned no matter what the composition, we do make available a suggested grid cleaning protocol.

We hope that this message has not been too confusing, but this is a controversial topic amount EM users and we are just trying to bring a bit more "light" to the discussion. We would welcome comments from customers of SPI grids who might want to share their own experiences with grid cleaning.


To Ask a Question or Make a Comment

To Place an Order or Request a Quote


Return to:


Tuesday February 09, 2010
© Copyright 2000 - 2010. By Structure Probe, Inc.
Contacting SPI Supplies and Structure Probe, Inc.
All rights reserved.
All trademarks and trade names are the property of their respective owners.
Privacy Policy

Worldwide Distributors, Representatives, and Agents Flag logo